![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1341746.1 : SL500 - Information on the PUA2 Dual Channel Fibre Channel Card
In this Document
Applies to:Sun StorageTek SL500 Modular Library System - Version: Not ApplicableInformation in this document applies to any platform. GoalInformation on the PUA2 Dual Channel Fibre Channel Card.SolutionRequirements:PUA2 Dual Channel FC Card - 1432 code level or later on the SL500 - SLC version 5.25 or later - Dual Channel FC Hardware Activation File From E-delivery Overview of the PUA2 Dual Channel FC Feature - The PUA2 card allows the customer to have two separate FC host interfaces to the SL500 library. When the dual-path FC option is activated, the additional interface can be used for increasing bandwidth or for redundancy. - Note: Failover requires suitable host software—failover is not automatic. - The dual-path FC feature has to be activated by installing the Hardware Activation file via SLC. If the dual-path FC feature isn’t activated then only port 1 of the PUA2 will be able to be used as a library control path. - The ports on the PUA2 card are 8GB Qlogic chips. E-Delivery site link (Hardware Activation Files & SLC): https://edelivery.oracle.com/ Note: The PUA2 is to be the replacement for the MPU2 card. Note: Refer to TIP:3000 Library Fibre Channel (MPU2/PUA2) Interface in the SL500 Diagnostic and Troubleshooting Guide for further diagnosis information. Attachments This solution has no attachment |
||||||||||||
|