Solution Type Technical Instruction Sure Solution 1336510.1 : How to Replace a Sun Fire X2250 Hard Disk Drive and Carrier:ATR:1336510.1:0
In this Document
Applies to:Sun Fire X2250 Server - Version: Not Applicable to Not Applicable - Release: N/A to N/AInformation in this document applies to any platform. GoalHow to Replace a Sun Fire X2250 Hard Disk Drive and Carrier.SolutionDISPATCH INSTRUCTIONSWHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?) Nothing beyond basic partner training to be qualified as a Sun Service Delivery Partner. TIME ESTIMATE: 60 minutes FIELD ENGINEER INSTRUCTIONS WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : The customer should conduct an orderly software and system shutdown. Also the customer should backup the data if needed. System power off is required if integrated-mirroring (IM) is not configured. WHAT ACTION DOES THE ENGINEER NEED TO TAKE: 1. If you are not using an integrated-mirroring (IM) configuration, you must power off the server before removing an HDD; it is not necessary to remove the cover. Power off the system. If you are using an IM configuration, start with Step 2 2. Squeeze the release latch on the HDD and carefully swing the arm to the left as far as it will go. 3. Grasp the carrier bezel with both hands and carefully pull the carrier out of the drive bay. 4. Squeeze the release latch on the HDD and carefully swing the arm to the left as far as it will go. 5. Grasping the body of the drive in both hands, carefully guide the connector end of the carrier into the drive bay, sliding the carrier into the bay until the latch engages and partially closes itself. 6. Push the latch forward until it locks to secure the carrier in place. OBTAIN CUSTOMER ACCEPTANCE WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: See chapter 4.5.3 Replacing a Hard Disk Drive and Carrier (Sun Fire X2250 Server Service Manual) REFERENCE: Sun Fire X2250 Server Service Manual http://download.oracle.com/docs/cd/E19121-01/sf.x2250/820-4593-12/ Detailed SVM instructions can be found at http://download.oracle.com/docs/cd/E19253-01/816-4520/troubleshoottasks-96/index.html See Document 1010946.1 for Detailed Veritas Volume Manager instructions. See Document 1002753.1 for Detailed ZFS instructions References<NOTE:1010946.1> - General Guidance for Diagnosis and Replacing SCSI/SAS/SATA/FC-AL Disks running on Oracle Servers with Solaris<NOTE:1002753.1> - How to replace a drive in Solaris[TM] ZFS Attachments This solution has no attachment |
||||||||||||
|