Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1334664.1
Update Date:2012-05-28
Keywords:

Solution Type  Technical Instruction Sure

Solution  1334664.1 :   How to Replace a Sun Netra T5440 BATTERY:ATR:1334664.1:0  


Related Items
  • Sun Netra T5440 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




Applies to:

Sun Netra T5440 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to Replace a Sun Netra T5440 Battery

Fix

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Sun Netra T5440 training.

TIME ESTIMATE: 30 minutes
TASK COMPLEXITY: 0

FIELD ENGINEER INSTRUCTIONS


PROBLEM OVERVIEW:Battery failure


WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

To prepare the server for installing the battery. Proceed with the following steps:

Powering Off the Server
Disconnecting Cables From the Server
Removing the Server From the Rack
Performing Antistatic Measures
Removing the Top Cover
Removing the PCI Mezzanine Assembly
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

Removing the Battery
1. Gently depress the release tab and pull the battery out of the battery housing.

Installing the Battery
1. Remove the replacement battery from its packaging.
2. Carefully press the new battery in the slot.

Returning the Server to Operation
1. Install the top cover.  (Position the top cover on the chassis, and tighten the two green captive screws on the rear of the top cove).
2. Install the server into the rack.
3. Cable the server.
4. Power on the server.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Verify functionality, no service LEDs or messages.

PARTS NOTE:  https://support.oracle.com/handbook_private/Systems/Netra_T5440/components.html#SystemBoard

REFERENCE INFORMATION:
http://download.oracle.com/docs/cd/E19874-01/820-4445-13/z40004091017446.html#bbjggjjc


Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback