Asset ID: |
1-71-1334664.1 |
Update Date: | 2012-05-28 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1334664.1
:
How to Replace a Sun Netra T5440 BATTERY:ATR:1334664.1:0
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
Applies to:
Sun Netra T5440 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Replace a Sun Netra T5440 Battery
Fix
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Sun Netra T5440 training.
TIME ESTIMATE: 30 minutes
TASK COMPLEXITY: 0
FIELD ENGINEER INSTRUCTIONS
PROBLEM OVERVIEW:Battery failure
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
To prepare the server for installing the battery. Proceed with the following steps:
Powering Off the Server
Disconnecting Cables From the Server
Removing the Server From the Rack
Performing Antistatic Measures
Removing the Top Cover
Removing the PCI Mezzanine Assembly
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Removing the Battery
1. Gently depress the release tab and pull the battery out of the battery housing.
Installing the Battery
1. Remove the replacement battery from its packaging.
2. Carefully press the new battery in the slot.
Returning the Server to Operation
1. Install the top cover. (Position the top cover on the chassis, and tighten the two green captive screws on the rear of the top cove).
2. Install the server into the rack.
3. Cable the server.
4. Power on the server.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Verify functionality, no service LEDs or messages.
PARTS NOTE: https://support.oracle.com/handbook_private/Systems/Netra_T5440/components.html#SystemBoard
REFERENCE INFORMATION:
http://download.oracle.com/docs/cd/E19874-01/820-4445-13/z40004091017446.html#bbjggjjc
Attachments
This solution has no attachment