Asset ID: |
1-71-1334631.1 |
Update Date: | 2012-08-30 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1334631.1
:
How to Replace Sun Netra T5440 PCI Cards:ATR:1334631.1:0
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
Applies to:
Sun Netra T5440 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Goal
Replace Sun Netra T5440 PCI-X and PCIe Cards.
*********************************************************************
To report errors or request improvements on this procedure,
please Add a Comment on Doc ID: 1334631.1
*********************************************************************
Fix
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Sun Netra T5440 training recommended but not required.
Time Estimate: 60 minutes
Task Complexity: 0
FIELD ENGINEER INSTRUCTIONS
PROBLEM OVERVIEW: PCI card failure
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
To prepare the server for PCI card removal. Proceed with the following steps:
Powering Off the Server
Disconnecting Cables From the Server
Removing the Server From the Rack
Performing Antistatic Measures
Removing the Top Cover
Removing the PCI Mezzanine Assembly
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Removing PCI-X and PCIe Cards
1. To remove the PCI air duct (slots 0-3 only): Lift it straight up
2. Release the PCI card release tab by pulling it up and to the left.
3. Remove the PCI card (Carefully lift it straight up)
Installing PCI-X and PCIe Cards
1. Insert the PCI card filler panel in the appropriate slot.
2. Secure the PCI card release tab.
3. Replace the PCI air duct (slots 0-3 only).
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE FE/CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot system and monitor boot sequence for errors. Test functionality of system:
1. Run the Solaris "fmadm faulty" and SP/ILOM "show faulty" command (if only ALOM is supported run "showfaults -v" command) to verify that the fault has been cleared.
2. Perform one of the following tasks based on your verification results:
* If the previous steps did not clear the fault, refer to doc 1004229.1 for information about the tools and methods you can use to diagnose and clear component faults.
* If the previous steps indicate that no faults have been detected, then the component has been replaced successfully. No further action is required
3. Restart software applications per applicable administration guides to resume system operation.
PARTS NOTE: https://support.oracle.com/handbook_private/Systems/Netra_T5440/components.html#Ethernet
REFERENCE INFORMATION:
http://download.oracle.com/docs/cd/E19874-01/820-4445-13/z40004091017446.html#cehihiji
Attachments
This solution has no attachment