Solution  1334182.1 :   How to Remove and Replace a SPARC T3-4 Server Fan Module:ATR:1334182.1:0  


Related Items
  • SPARC T3-4
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
  Goal
  Solution


Applies to:

SPARC T3-4 - Version: Not Applicable and later   [Release: N/A and later ]
Information in this document applies to any platform.

Goal

How to remove and replace a SPARC T3-4 Server Fan Module

Solution


CAP PROBLEM OVERVIEW: How to remove and replace a SPARC T3-4 Server Fan Module

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)

CRU procedure.
The fan module is a hot-service component that can be replaced by a customer.

Time Estimate: 30 minutes

Task Complexity: 0

FIELD ENGINEER INSTRUCTIONS

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

Take ESD Precautions

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

Remove a Fan Module

The fan module is a hot-service component that can be replaced by a customer.

1. Locate the faulty fan module that you want to remove from the server.

2. Determine if you can remove the fan module with the server running or not.
Refer to T3-4 Service Guide to determine if you can remove a fan
module with the server running or if you must shut down the server before removing a fan module.
If you can remove a fan module with the server running, go to Step 3.
If you cannot remove a fan module with the server running, refer to the T3-4 Service Guide on how to power down the server before continuing.

3. Press down on the middle portion of the fan lever and lower the lever slightly to disengage the fan latch.

4. Lower the fan lever completely and pull out on the fan module to remove the fan module from the system.

Install a Fan Module

1. Insert the fan module into the empty fan module slot.

2. Lift the fan lever up completely until the latch clicks into place to completely seat the fan module into the slot.

3. Power on the server, if necessary.
If you had to power off the server before removing and installing a new fan, refer to the T3-4 Service Guide on how to return the server to operation and also how to power on again.

4. Verify the fan module functionality.


Verify Fan Module Functionality

1. Check the front or rear panel LEDs for the following indications:
 - Green System OK LED illuminated
 - Amber System Fault LED not illuminated
 - Amber System Fan Fault LED not illuminated

2. Run the ILOM show faulty command to check for faults.
If no faults are reported, then the fan module has been replaced successfully.
No further action is required.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Verify functionality, no service LEDs or messages