Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1334175.1
Update Date:2012-08-01
Keywords:

Solution Type  Technical Instruction Sure

Solution  1334175.1 :   How to Remove and Replace a SPARC T3-4 Server DIMM:ATR:1334175.1:0  


Related Items
  • SPARC T3-4
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Fix


Applies to:

SPARC T3-4 - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to remove and replace a DIMM

Fix

CAP PROBLEM OVERVIEW: How to remove and replace a DIMM

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Qualified service technicians with SPARC T3-4 experience/training.

Time Estimate: 30 minutes

Task Complexity: 0

FIELD ENGINEER INSTRUCTIONS

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Remove a DIMM

A DIMM is a cold-service component that can be replaced by a customer.
Before beginning this procedure, ensure that you are familiar with the cautions and safety instructions.
Caution: Do not leave DIMM slots empty. You must install filler panels in all empty DIMM slots.

1. Take the necessary ESD precautions.

2. Remove the processor module with the faulty DIMM from the server and
remove the cover from the processor module, if you have not already done so.

3. Locate the DIMMs that need to be replaced.

4. Push down on the ejector tabs on each side of the DIMM until the DIMM is released.
Caution:  DIMMs and heat sinks on the motherboard might be hot.

5. Grasp the top corners of the faulty DIMM and lift it out of its slot.

6. Place the DIMM on an antistatic mat.

7. Repeat Step 4 through Step 6 for any other DIMMs you intend to remove.

8. Determine if you will be installing replacement DIMMs at this time.

If you will be installing replacement DIMMs at this time, then proceed to the Install a Dimm section below.

If you will not be installing replacement DIMMs at this time, follow these procedures to reinsert the processor module back into the server:
a. Install filler panels in the empty DIMM slots.
Caution: Do not leave DIMM slots empty. You must install filler panels in all empty DIMM slots.
b. Place the cover back onto the processor module and insert the processor module back into its slot in the server.

Install a DIMM

1. Take the necessary ESD precautions.

2. Remove the processor module from the server and remove the cover from the processor module, if you have not already done so.

3. Unpack the replacement DIMMs and place them on an antistatic mat.

4. Ensure that the ejector tabs on the connector that will receive the DIMM are in the open position.

5. Align the DIMM notch with the key in the connector.
Caution: Ensure that the orientation is correct. The DIMM might be damaged if the orientation is reversed.

6. Push the DIMM into the connector until the ejector tabs lock the DIMM in place.
If the DIMM does not easily seat into the connector, check the DIMMs orientation.

7. Repeat Step 4 through Step 6 until all new DIMMs are installed.

8. Place the cover back onto the processor module and insert the processor module back into its slot in the server.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE FE/CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Boot system and monitor boot sequence for errors. Test functionality of system:
1. Run the Solaris "fmadm faulty" and SP/ILOM "show faulty" command (if only ALOM is supported run "showfaults -v" command) to verify that the fault has been cleared.
2. Perform one of the following tasks based on your verification results:
   * If the previous steps did not clear the fault, refer to doc 1004229.1 for information about the tools and methods you can use to diagnose and clear component faults.
   * If the previous steps indicate that no faults have been detected, the component has been replaced successfully. No further action is required
3. Restart software applications per applicable administration guides to resume system operation.

PARTS NOTE:

REFERENCE INFORMATION:

SPARC T3-4 Server Service Guide: http://docs.oracle.com/cd/E19417-01/E20812/gentextid-6532.html#scrolltoc


Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback