Goal
How to Replace a Sun Fire T1000 Server Clock Battery
Fix
DISPATCH INSTRUCTIONS
The coin cell battery should be retrieved from your personal stock of coin cell batteries. If you have a battery, please cancel the part order and then accept the task. If you require this order to proceed, please do not cancel the part order and accept the task as normal.
WHAT SKILLS DOES THE ENGINEER NEED:
Nothing beyond basic product training.
TIME ESTIMATE: 60 minutes
TASK COMPLEXITY: 0
FIELD ENGINEER INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
The customer should conduct an orderly software and system shutdown.
System power off is required.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Ensure system is shut down
2. Follow instructions in chapter 4 (Sun Fire T1000 Server Service Manual) to prepare the system for service.
The chassis cover might be very difficult to remove. If you press too hard on the cover lock button, the front edge of the cover might warp and bind. Also, elastic gasket material on the sides of the chassis might prevent the cover from sliding freely.
To work around this, lightly hold down the cover lock button and push the cover slightly toward the front of the chassis (this assists the unlocking action), then slide the cover approximately one half inch (12 mm) toward the rear of the chassis. You can now lift the cover off the chassis.
3. Using a small flathead screwdriver, carefully pry the battery from the motherboard.
4. Unpack the replacement battery.
5. Press the new battery into the motherboard with the + facing upward.
6. Follow instructions in Chapter 6 (Sun Fire T1000 Server Service Manual) to finish up hardware servicing.
7. Use ALOM commands to verify and set the date and time if required.
sc> showdate
sc> setdate mmddHHMMccyy.SS
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Power on the server.
PARTS NOTE:
150-1204
REFERENCE INFORMATION:
Sun Fire T1000 Server Service Manual
Attachments
This solution has no attachment