In this Document
Goal
Fix


Applies to:

Sun Blade X6240 Server Module - Version Not Applicable and later
Sun Blade 6000 System - Version Not Applicable and later
Sun Blade 6048 System - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to Remove and Replace a X6240 Raid Expansion Module

Fix

CAP PROBLEM OVERVIEW: Raid Expansion Module Replacement

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
X6240 Hardware experience.

Time Estimate: 60 minutes

FIELD ENGINEER INSTRUCTIONS

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

* Orderly shutdown of applications on server
* Full backup is recommended as a precaution
* Shutdown of OS and power down of server
* Caution – Do not operate the system with empty slots. Always insert a filler panel into an empty slot to reduce the possibility of system shut down.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

Remove the main cover

If the REM board uses a backup battery, disconnect the jumper cable between the REM board and chassis motherboard.

Remove the existing REM board or the cap(s) from the REM connector(s) if either is present.

Slide the REM board at an angle into the support bracket, then press it carefully into the connector.

If the REM board uses a backup battery, connect the jumper cable between the REM board and chassis motherboard.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

PARTS NOTE:

REFERENCE INFORMATION:
Sun Blade X6240 Server Module Service Manual
http://download.oracle.com/docs/cd/E19045-01/blade.x6240/820-3971-11/