Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1333636.1
Update Date:2012-08-02
Keywords:

Solution Type  Technical Instruction Sure

Solution  1333636.1 :   How to Remove and Replace an X6240 Fabric Expansion Module (FEM):ATR:2272:0  


Related Items
  • Sun Blade 6000 System
  •  
  • Sun Blade X6240 Server Module
  •  
  • Sun Blade 6048 System
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Fix


Applies to:

Sun Blade X6240 Server Module - Version Not Applicable and later
Sun Blade 6000 System - Version Not Applicable and later
Sun Blade 6048 System - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to Remove and Replace a X6240 Fabric Expansion Module

Fix

CAP PROBLEM OVERVIEW: Replacing a Fabric Expansion Module (FEM)

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Experience replacing the X6240 Fabric Expansion Module.

TIME ESTIMATE: 60 minutes

ENGINEER INSTRUCTIONS

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

* Orderly shutdown of applications on server
* Full backup is recommended as a precaution
* Shutdown of OS and power down of server
* Caution - Do not operate the system with empty slots. Always insert a filler panel into an empty slot to reduce the possibility of system shut down.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

* Power off the server and remove the server module from the chassis
* Remove the main cover
* Remove the existing FEM board or the cap from the FEM connector if either is present.
The cap should only be present if you are adding a FEM board to a server module without one.
* Slide the FEM board at an angle into the support bracket, then press it carefully
into the connector.
* Installation is the reverse of this procedure.

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

PARTS NOTE:

REFERENCE INFORMATION:

Sun Blade X6240 Server Module Service Manual

http://download.oracle.com/docs/cd/E19045-01/blade.x6240/820-3971-11/index.html



Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback