VTL/PTL/KMA/Media Server -Shutdown and Start-Up Procedure
Related Items |
- Sun StorageTek VTL Plus Storage Appliance
- Sun StorageTek SL500 Modular Library System
- Oracle Key Manager
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Backup Software-Filesystems>SN-TP: Encryption
|
In this Document
Applies to:
Oracle Key Manager - Version 2.0.0 and later
Sun StorageTek VTL Plus Storage Appliance - Version 1.0 - Build 1323 and later
Sun StorageTek SL500 Modular Library System - Version Not Applicable and later
Information in this document applies to any platform.
Goal
Customer is going to shutdown and start up the following Oracle Devices as a Production Datacenter UPS Power migration activity.
Customer would like to know exact step by step procedures of Shutdown and Start up for the below mentioned oracle devices.
Device Details are given below:
VTL:
SUN Stor Tek SL500 1300
Serial:55700200731
Valid :31-Aug-12
---------------
PTL:
SUN Stor Tek VTL Prime 4320C
Serial:0924AK2280
Valid :31-Aug-12
---------------
KMA:
2x Crypto-KMA-2
Serial:5750004020093,5750004020087
Valid :31-Aug-12
---------------
Media Server:
Name: Nmesgp11 (Media Server)
Manufacturer: Sun Microsystems
Product Name: SUN FIRE X4250
Version: Rev 50
Serial Number: 0926QAA004
Fix
The "exact" processes are documented in the User Guides or Admin Guides for each product.
Generally speaking, the following would a suggested action plan.
Stop all processes that use tape. Backup, recovery and any other tape processes.
Shut down the applications that drive backup, recovery and any other tape processes.
Shut down the servers that run the applications that drive backup, recovery and other tape processes.
Make sure there are no tapes left in tape drives or the library CAP.
You are now free to shutdown the VTL application, and power off the associated server.
Shutdown and power off the KMA's
Shutdown and power off the library.
Again, exactly how these applications and devices are shutdown are included in the User or Admin Guides.
To bring everything back, reverse this process, with one added note.
Verify the customer's network is backup and working (especially the one used by the KMA's) before starting to bring up anything tape related.
Related documentation:
Doc ID 1019656.1 on how to Shutdown and reboot a KMA
Doc ID 1022256.1 on Shutting down or rebooting a Solaris VTL server.