Asset ID: |
1-71-1332545.1 |
Update Date: | 2012-07-26 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1332545.1
:
How to Remove and Replace an x4275 Cable Kit:ATR:1958:0
Related Items |
- Sun Fire X4275 Server
- Exadata Database Machine V2
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Fire X4275 Server - Version Not Applicable and later
Exadata Database Machine V2 - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to remove and replace an x4275 Cable Kit
Fix
CAP PROBLEM OVERVIEW: Replacing Cable Kit (Backplane Power/I2C Cables, Fan Power/I2C Cables)
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
No specific skills required
DELIVERY REQUIREMENT:
Immediate
TIME ESTIMATE: 30 minutes
FIELD ENGINEER INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
customer should perform an orderly and graceful shutdown of applications and OS
A data backup is not a pre-requisite but is a wise precaution
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Follow standard ESD procedures
1. Power off the server and unplug (REMOVE) the power cords from power supplies
2. Remove the top cover
3. Review wiring diagram at below reference location for cable connections between IO connector board, fan board and disk backplane
4. Replace top cover
5. Re-attach power cords to power supplies
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot up system and verify full functionality
PARTS NOTE:
REFERENCE INFORMATION:
Wiring Diagram
https://support.oracle.com/handbook_private/Systems/SunFireX4275/wiring_1.html
Front Connector Assembly
https://support.oracle.com/handbook_private/Devices/I_O/IO_SunFireX4275_Connector_Assy.html
Attachments
This solution has no attachment