How to remove and replace an x4275 Fan Module:ATR:1947:0
Related Items |
- Sun Fire X4275 Server
- Exadata Database Machine V2
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Fire X4275 Server - Version Not Applicable and later
Exadata Database Machine V2 - Version Not Applicable and later
Information in this document applies to any platform.
Goal
Remove and replace an x4275 Fan Module
Fix
CAP PROBLEM OVERVIEW: Failed/Faulty Fan Module
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
No specific training required
TIME ESTIMATE: 15 minutes
FIELD ENGINEER INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
The fan module is hot swappable.
Caution: Leaving the fan module door open for longer than 60 seconds may cause the server to overheat and shutdown.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Open the fan module door/cover by pulling the release tabs
2. Identify the faulty fan by the Service Action required LED for that fan module
3. Grasp the fan module using thumb and forefinger and remove from the system (DO NOT rock the module back and forth whilst removing)
4. Install the replacement fan module into the slot ensuring correct orientation. Ensure it is fully seated and the LED is not lit
5. Close the fan module door/cover
6. Verify Service LEDs are not lit
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Verify functionality
PARTS NOTE:
REFERENCE INFORMATION:
Sun Fire X4170, X4270, and X4275 Servers Service Manual