![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1329203.1 : VSM/SVA - Power FSC79F0 or FSC79F1, then FSC7A00 or FSC7A01
In this Document Created from <SR 3-3782400277>
Applies to:Sun StorageTek V2X SVA Disk System - Version: Not ApplicableSun StorageTek VSM System - Version: 4 to 5C [Release: 4.0 to 5.0] Information in this document applies to any platform. GoalTroubleshooting Power FSC79F0 or FSC79F1 followed later by FSC7A00 or FSC7A01SolutionFSC79F0 and FSC79F1 indicate a loss of AC power to region 0 and region 1 respectivelyFSC7A00 and FSC7A01 indicate a return of AC power to region 0 and region 1 respectively This combination of FSC codes often occurs when the customer has had a site power outage and recovered, or is working on their site power/UPS. 1. Connect to the box and verify there are no fenced power supplies 2. If there is one or more fenced power supplies, send an FSE on site to either GFR/no replace the power supply, or GFR/replace the power supply. Attachments This solution has no attachment |
||||||||||||
|