![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1329201.1 : VSM/SVA - How to Troubleshoot FSC7C24
In this Document
Applies to:Sun StorageTek VSM System - Version: 4 to 5C - Release: 4.0 to 5.0Sun StorageTek V2X SVA Disk System - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Information in this document applies to any platform. GoalHow to troubleshoot FSC7C24FSC7C24_IT_PS_FAIL 0x7C24 CSE: @SAME ENG: This power supply is not producing any output. The N_INT line is asserted. Solution1. Connect to the failing box with CSRC or DOP.2. Identify the failing power supply (fenced=yes) and part number 3. Send an FSE on site to replace the failing power supply Attachments This solution has no attachment |
||||||||||||
|