How to Replace a Netra X6270 M2 and Blade X6270 M2 Memory DIMM:ATR:2283:0
Related Items |
- Sun Blade 6000 System
- Sun Netra X6270 M2 Server Module
- Sun Blade 6048 System
- Sun Blade X6270 M2 Server Module
- Sun Netra 6000 System
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Blade X6270 M2 Server Module - Version Not Applicable and later
Sun Netra X6270 M2 Server Module - Version Not Applicable and later
Sun Blade 6000 System - Version Not Applicable and later
Sun Blade 6048 System - Version Not Applicable and later
Sun Netra 6000 System - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Replace a Netra X6270 M2 and Blade X6270 M2 Memory DIMM
Fix
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
No specific skills required.
Time Estimate: 30 minutes
FIELD ENGINEER INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
- Data backup not required but recommended as a precaution.
- Orderly shutdown of applications, then the OS and power down of server.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1.Prepare for servicing:
a. Attach an antistatic wrist strap.
b. Power off the server.
c. Extend the server to the maintenance position.
d. Remove the top cover.
To remove faulty DIMM,
a. Identify the location of the faulty.(LED is off: DIMM is operating properly, LED is on (amber): DIMM is faulty and should be replaced.)
b.Rotate both DIMM slot ejectors outward
Caution – If you are not immediately inserting a replacement DIMM into the empty
DIMM socket, you should insert a DIMM filler panel in the socket.
To install a DIMM,
a. Determine the DIMM socket location to populate.
Note – If the DIMM socket contains a filler panel, you will need to remove the
DIMM filler panel prior to installing a DIMM into the DIMM socket.
b. Ensure that the ejector lever at each end of the memory socket are fully open
(rotated outward) to accept the new DIMM.
c. Align the DIMM notch to the DIMM connector key.
d. Using both thumbs, press the DIMM straight down into the DIMM
connector slot until both ejector levers close.
Install the cover on the server.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot up system and verify full functionality
REFERENCE INFORMATION:
Sun Blade X6270 M2 Server Module Service Manual
http://download.oracle.com/docs/cd/E19474-01/
Sun Netra X6270 M2 Server Module Service Manual
http://docs.oracle.com/cd/E19472-01/821-0939-10/index.html