Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1320258.1
Update Date:2012-07-31
Keywords:

Solution Type  Technical Instruction Sure

Solution  1320258.1 :   How to Replace a Netra X6270 M2 and Blade X6270 M2 System Battery:ATR:2286:0  


Related Items
  • Sun Blade 6000 System
  •  
  • Sun Netra X6270 M2 Server Module
  •  
  • Sun Blade 6048 System
  •  
  • Sun Netra 6000 System
  •  
  • Sun Blade X6270 M2 Server Module
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Fix


Applies to:

Sun Blade X6270 M2 Server Module - Version Not Applicable and later
Sun Netra X6270 M2 Server Module - Version Not Applicable and later
Sun Blade 6000 System - Version Not Applicable and later
Sun Blade 6048 System - Version Not Applicable and later
Sun Netra 6000 System - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to Replace a Netra X6270 M2 and Blade X6270 M2 System Battery

Fix

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
No specific skills required

DELIVERY REQUIREMENT:
Maintenance window may be required

TIME ESTIMATE: 15 minutes

FIELD ENGINEER INSTRUCTIONS

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

Caution – Removing the system battery will clear the CMOS and return the BIOS settings to their factory defaults. The BIOS will automatically notify you of this change the next time you boot the system.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

Prepare the server for service.

a. Power off the server and disconnect the power cord (s) from the power supply (s).

b. Remove the server from the rack.

c. Attach an antistatic wrist strap.

d. Remove the top cover.

To remove and install the system battery,

a. Using your fingers, unlatch the battery from the socket by twisting the battery away from the socket spring.

b. Lift the battery up and out of the socket,

c. Locate the replacement system battery then insert the battery into the socket with the positive (+) side of the battery facing toward the spring.

Install the cover on the server.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Boot up system and verify full functionality

PARTS NOTE:

# 150-3993

REFERENCE INFORMATION:
Sun Blade X6270 M2 Server Module Service Manual
http://download.oracle.com/docs/cd/E19474-01/

Sun Netra X6270 M2 Server Module Service Manual
http://docs.oracle.com/cd/E19472-01/821-0939-10/index.html


Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback