Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1320257.1
Update Date:2012-07-31
Keywords:

Solution Type  Technical Instruction Sure

Solution  1320257.1 :   How to Replace a Netra X6270 M2 and Blade X6270 M2 RAID Expansion Module:ATR:2285:0  


Related Items
  • Sun Blade 6000 System
  •  
  • Sun Netra X6270 M2 Server Module
  •  
  • Sun Blade 6048 System
  •  
  • Sun Blade X6270 M2 Server Module
  •  
  • Sun Netra 6000 System
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Fix


Applies to:

Sun Blade X6270 M2 Server Module - Version Not Applicable and later
Sun Netra X6270 M2 Server Module - Version Not Applicable and later
Sun Blade 6000 System - Version Not Applicable and later
Sun Blade 6048 System - Version Not Applicable and later
Sun Netra 6000 System - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to Replace a Netra X6270 M2 and Blade X6270 M2 RAID Expansion Module

Fix

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
No specific skills required

DELIVERY REQUIREMENT:
Maintenance window may be required

TIME ESTIMATE: 30 minutes

FIELD ENGINEER INSTRUCTIONS

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

Data backup not required but recommended as a precaution.
Orderly shutdown of applications.
Shutdown of OS and power down of server.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

Prepare the server for service.

a. Power off the server and disconnect the power cord (s) from the power supply (s).

b. Remove the server from the rack.

c. Attach an antistatic wrist strap.

d. Remove the top cover.

Install a new REM,

Locate the REM support bracket on the motherboard, and slide the REM card at an angle into the support bracket, then press the module carefully into the connector.

■ If you are adding a REM to a system without a REM, continue performing the remaining steps in this procedure.

Caution -- The following steps will remove all data from the system. Back up your data to an external site before proceeding.

Replace an Existing REM,

Remove the existing REM card.

Slide the REM card at an angle into the support bracket, then press it carefully into the connector.

Connect the REM to the hard disk drives or solids state drives using the REM SAS cable.

Install the cover on the server.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot up system and verify full functionality

PARTS NOTE:

REFERENCE INFORMATION:
Sun Blade X6270 M2 Server Module Service Manual
http://download.oracle.com/docs/cd/E19474-01/

Sun Netra X6270 M2 Server Module Service Manual
http://docs.oracle.com/cd/E19472-01/821-0939-10/index.html


Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.