Asset ID: |
1-71-1320257.1 |
Update Date: | 2012-07-31 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1320257.1
:
How to Replace a Netra X6270 M2 and Blade X6270 M2 RAID Expansion Module:ATR:2285:0
Related Items |
- Sun Blade 6000 System
- Sun Netra X6270 M2 Server Module
- Sun Blade 6048 System
- Sun Blade X6270 M2 Server Module
- Sun Netra 6000 System
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Blade X6270 M2 Server Module - Version Not Applicable and later
Sun Netra X6270 M2 Server Module - Version Not Applicable and later
Sun Blade 6000 System - Version Not Applicable and later
Sun Blade 6048 System - Version Not Applicable and later
Sun Netra 6000 System - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Replace a Netra X6270 M2 and Blade X6270 M2 RAID Expansion Module
Fix
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
No specific skills required
DELIVERY REQUIREMENT:
Maintenance window may be required
TIME ESTIMATE: 30 minutes
FIELD ENGINEER INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
Data backup not required but recommended as a precaution.
Orderly shutdown of applications.
Shutdown of OS and power down of server.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Prepare the server for service.
a. Power off the server and disconnect the power cord (s) from the power supply (s).
b. Remove the server from the rack.
c. Attach an antistatic wrist strap.
d. Remove the top cover.
Install a new REM,
Locate the REM support bracket on the motherboard, and slide the REM card at an angle into the support bracket, then press the module carefully into the connector.
■ If you are adding a REM to a system without a REM, continue performing the remaining steps in this procedure.
Caution -- The following steps will remove all data from the system. Back up your data to an external site before proceeding.
Replace an Existing REM,
Remove the existing REM card.
Slide the REM card at an angle into the support bracket, then press it carefully into the connector.
Connect the REM to the hard disk drives or solids state drives using the REM SAS cable.
Install the cover on the server.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot up system and verify full functionality
PARTS NOTE:
REFERENCE INFORMATION:
Sun Blade X6270 M2 Server Module Service Manual
http://download.oracle.com/docs/cd/E19474-01/
Sun Netra X6270 M2 Server Module Service Manual
http://docs.oracle.com/cd/E19472-01/821-0939-10/index.html
Attachments
This solution has no attachment