Asset ID: |
1-71-1320253.1 |
Update Date: | 2012-07-31 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1320253.1
:
How to Replace a Netra X6270 M2 and Blade X6270 M2 PCIe Fabric Expansion Module:ATR:2281:0
Related Items |
- Sun Blade 6000 System
- Sun Netra X6270 M2 Server Module
- Sun Blade 6048 System
- Sun Blade X6270 M2 Server Module
- Sun Netra 6000 System
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Blade X6270 M2 Server Module - Version Not Applicable and later
Sun Netra X6270 M2 Server Module - Version Not Applicable and later
Sun Blade 6000 System - Version Not Applicable and later
Sun Blade 6048 System - Version Not Applicable and later
Sun Netra 6000 System - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Replace a Netra X6270 M2 and Blade X6270 M2 PCIe Fabric Expansion Module (FEM)
Fix
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
CRU
DELIVERY REQUIREMENT:
schedule with maintenance window
TIME ESTIMATE: 30 minutes
FIELD ENGINEER INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
This procedure requires a complete shut down of the equipment.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1.- Removing FEM Card.
a. Power off the server and disconnect the power cord (s) from the power supply (s).
b. Remove the server from the rack.
c. Attach an antistatic wrist strap.
d. Remove the top cover.
e.-Remove the existing FEM card.
2.- Installing FEM Card.
Perform the following steps to install the FEM card:
- Slide the FEM card at an angle into the support bracket.
- Press the FEM card carefully into the connector.
- Connect the FEM to the motherboard.
- Install the cover on the server.
3.-Return the server to operation.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Boot up system and verify full functionality
PARTS NOTE:
REFERENCE INFORMATION:
Sun Blade X6270 M2 Server Module Service Manual
http://download.oracle.com/docs/cd/E19474-01/
Sun Netra X6270 M2 Server Module Service Manual
http://docs.oracle.com/cd/E19472-01/821-0939-10/index.html
Attachments
This solution has no attachment