In this Document
Goal
Fix


Applies to:

Sun Blade X6270 Server Module - Version Not Applicable and later
Sun Blade 6000 System - Version Not Applicable and later
Sun Blade 6048 System - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to remove and replace a Fabric Expansion Module (FEM) in a Sun Blade X6270 Server Module

Fix

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Field Engineer skills

DELIVERY REQUIREMENT:
Schedule with maintenance window

TIME ESTIMATE: 30 minutes

FIELD ENGINEER INSTRUCTIONS

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Replace a FEM Card

1. Power off the server and remove the server from the chassis.
Caution - After removing the server from the chassis insert a filler panel into an empty slot to reduce the possibility of a system shutdown.
2. Remove the cover from the server.
3. Perform one of the following:
* Remove the existing FEM board.
or
* Remove protective shipping cap from the FEM connector.
4. Perform the following steps to install the FEM board:
a. Slide the FEM board at an angle into the support bracket
b. Press the FEM board carefully into the connector.
5. Install the cover on the server.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

PARTS NOTE:

REFERENCE INFORMATION: