DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Field Engineer skills
DELIVERY REQUIREMENT:
Schedule with maintenance window
TIME ESTIMATE: 30 minutes
FIELD ENGINEER INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Replace a FEM Card
1. Power off the server and remove the server from the chassis.
Caution - After removing the server from the chassis insert a filler panel into an empty slot to reduce the possibility of a system shutdown.
2. Remove the cover from the server.
3. Perform one of the following:
* Remove the existing FEM board.
or
* Remove protective shipping cap from the FEM connector.
4. Perform the following steps to install the FEM board:
a. Slide the FEM board at an angle into the support bracket
b. Press the FEM board carefully into the connector.
5. Install the cover on the server.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
PARTS NOTE:
REFERENCE INFORMATION: