How to Replace a X6270 REM 4620A:ATR:2305:0
Related Items |
- Sun Blade 6000 System
- Sun Blade X6270 Server Module
- Sun Blade 6048 System
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Blade X6270 Server Module - Version Not Applicable and later
Sun Blade 6000 System - Version Not Applicable and later
Sun Blade 6048 System - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to remove and replace a RAID Expansion Module 4620A in a Sun Blade X6270 Server Module
Fix
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Field Engineer skills
DELIVERY REQUIREMENT:
Schedule with maintenance window
TIME ESTIMATE: 45 minutes
FIELD ENGINEER INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Replace a REM Card
Note: With the cover off of the server module, determine whether the REM battery is attached directly onto the motherboard or on the REM card 4620A.
Replace a REM Card 4620A When the REM Battery Is Installed on the REM Card
1. Remove the existing REM card by sliding it at an angle out of the support bracket.
2. Swap the REM battery from the existing REM card to the new REM card.
3. Replace the REM card by sliding the new card at an angle into the support bracket, then pressing it carefully into its connector.
4. Install the cover on the server.
Replace a REM Card 4620A When the REM Battery Is Installed on the Motherboard
1. Disconnect the REM card battery cable from the motherboard.
2. Remove the existing REM card by sliding the card at an angle out of the support bracket.
3. Reconnect the battery cable to the motherboard and the new REM card.
4. Replace the REM card by sliding it at an angle into the support bracket, then pressing it carefully into its connector.
5. Install the cover on the server.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
PARTS NOTE:
REFERENCE INFORMATION: