Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1319788.1
Update Date:2012-08-08
Keywords:

Solution Type  Technical Instruction Sure

Solution  1319788.1 :   How to Replace a REM Battery in a X6270:ATR:2304:0  


Related Items
  • Sun Blade 6000 System
  •  
  • Sun Blade X6270 Server Module
  •  
  • Sun Blade 6048 System
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Fix


Applies to:

Sun Blade X6270 Server Module - Version Not Applicable and later
Sun Blade 6000 System - Version Not Applicable and later
Sun Blade 6048 System - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to remove and replace a RAID Expansion Module Battery in a Sun Blade X6270 Server Module

Fix

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Field Engineer skills

DELIVERY REQUIREMENT:
Schedule with maintenance window

TIME ESTIMATE: 30 minutes

FIELD ENGINEER INSTRUCTIONS

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

Replace a REM Battery on the REM Card

1. Remove the cover from the server.
2. Disconnect the REM cable and remove the REM card from the chassis.
3. Remove the REM battery from the REM card by removing the four screws securing the old REM battery to the card.
4. Attach the new battery to the REM card with four screws.
5. Install the cover on the server.

Replace a REM Battery on the Motherboard

1. Remove the cover from the server.
2. Remove the two screws securing the battery to the bracket (see FIGURE 3-16).
3. Place the new battery on bracket and attach it using the two screws.
4. Plug the battery cable into the motherboard.
5. Install the cover on the server.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: