Asset ID: |
1-71-1317384.1 |
Update Date: | 2012-08-08 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1317384.1
:
How to Remove and Replace X6440 FEM:ATR:2298:0
Related Items |
- Sun Blade 6000 System
- Sun Blade X6440 Server Module
- Sun Blade 6048 System
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Blade X6440 Server Module - Version Not Applicable and later
Sun Blade 6000 System - Version Not Applicable and later
Sun Blade 6048 System - Version Not Applicable and later
Information in this document applies to any platform.
Goal
X6440 FEM Replacement
Fix
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
X6440 trained
DELIVERY REQUIREMENT:
schedule with maintenance window
TIME ESTIMATE: 30 minutes
FIELD ENGINEER INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
* The server must be fully shut down and the power cords disconnected.
* Do not operate the system with empty slots. Always insert a filler panel into an empty slot to reduce the possibility of system shut down.
* Take ESD Precautions.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Power off the server and remove the server module from the chassis
2. Remove the main cover
3. Remove the existing FEM board or the cap from the FEM connector if either is present.
4. Slide the FEM board at an angle into the support bracket, then press it carefully into the connector.
Installation is the reverse of these procedures.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Verify functionality, no service LEDs or messages
PARTS NOTE:
REFERENCE INFORMATION:
https://support.oracle.com/handbook_private/Systems/SunBladeX6440/component.top.html
Maintenance and Operations Documentation
http://download.oracle.com/docs/cd/E19045-01/blade.x6440/index.html
Attachments
This solution has no attachment