Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1316208.1
Update Date:2012-07-26
Keywords:

Solution Type  Technical Instruction Sure

Solution  1316208.1 :   How to remove and replace a Power Distribution Board Cable in an X4270 M2:ATR:2127:0  


Related Items
  • Exadata Database Machine X2-8
  •  
  • SPARC SuperCluster T4-4
  •  
  • Exadata Database Machine X2-2 Full Rack
  •  
  • SPARC SuperCluster T4-4 Half Rack
  •  
  • Exadata Database Machine X2-2 Qtr Rack
  •  
  • Exadata Database Machine X2-2 Half Rack
  •  
  • Exadata Database Machine X2-2 Hardware
  •  
  • Big Data Appliance Hardware
  •  
  • Sun Fire X4270 M2 Server
  •  
  • SPARC SuperCluster T4-4 Full Rack
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Fix


Applies to:

Big Data Appliance Hardware - Version Not Applicable and later
Exadata Database Machine X2-2 Qtr Rack - Version Not Applicable and later
Exadata Database Machine X2-2 Half Rack - Version Not Applicable and later
Exadata Database Machine X2-2 Full Rack - Version Not Applicable and later
Exadata Database Machine X2-8 - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to remove and replace a Power Distribution Board Cable in an X4270 M2

Fix

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
X64 Server Experience

TIME ESTIMATE: 30 minutes

FIELD ENGINEER INSTRUCTIONS

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
1. Prepare the server for service.
   a. Power off the server and disconnect the power cord (or cords) from the power supply (or supplies).
   b. Remove the server from the rack.
   c. Attach an antistatic wrist strap.
   d. Remove the top cover.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

Remove Power Distribution Board Cable

2. Remove the power distribution board cable .
  a. Release the latches on either side of the connector on the power distribution board and pull the cable straight up to disconnect it from the connector [1].
  b. Release the latches on either side of the connector on the motherboard, and pull the cable straight up to disconnect it from the connector [1].

Install Power Distribution Board Cable

1.Open the latches on the power distribution board connector.
2. Ensure that the key on the cable connector lines up with the slot on the board connector.
3. Push the cable connector into the power distribution board connector until seated and the latches close: When cable connector is properly seated the latches should be above the connector housing.
4. Carefully align the motherboard connector to the motherboard pin field.
5. Gently press the connector down until seated. If you feel significant resistance, stop and check the pin alignment.
6. Return the server to operation.
   a. Install the top cover.
   b. Return the server to the normal rack position.
   c. Reconnect the power cord(s) to the power supply (or supplies) and power on the server. Verify that the AC Present LED is lit.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

PARTS NOTE:
Caution - The system supplies power to the cables even when the server is powered off. To avoid personal injury or damage to the server, you must disconnect power cords before servicing the cables.

REFERENCE INFORMATION:

Sun Fire X4270 M2 Server Service Manual
http://download.oracle.com/docs/cd/E19245-01/E21671-02/index.html