Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1313780.1
Update Date:2011-11-07
Keywords:

Solution Type  Technical Instruction Sure

Solution  1313780.1 :   How to Remove and Replace an x4600 PCI Card:ATR:1223:0  


Related Items
  • Sun Fire X4600 M2 Server
  •  
  • Sun Fire X4600 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
  Goal
  Solution


Applies to:

Sun Fire X4600 Server - Version: Not Applicable to Not Applicable - Release: N/A to N/A
Sun Fire X4600 M2 Server - Version: Not Applicable to Not Applicable   [Release: N/A to N/A]
Information in this document applies to any platform.

Goal

How to remove and replace an x4600 PCI Card

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
No specific skills required

TIME ESTIMATE: 45 minutes

DELIVERY REQUIREMENT:
Immediate

TASK COMPLEXITY: 0

FIELD ENGINEER INSTRUCTIONS
PROBLEM OVERVIEW:
Faulty or defective PCI Card.

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE
RESOLUTION ACTIVITY?
Data backup not required but recommended as a precaution.
Orderly shutdown of applications.
Shutdown of OS and power down of server.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Ensure standard ESD procedures are followed
1. Power off the server and unplug (REMOVE) the power cords
2. Remove the main cover
3. Locate the PCI card to be replaced
4. Label cables and disconnect from existing PCI card
5. Release the PCI card by moving the locking lever upward and carefully remove the PCI card by pulling up
6. Install the replacement PCI card into the slot, ensure it is engage properly
7. Close the locking lever over the rear connector of the PCI card
8. Replace the main cover
9. Re-attach the power cords

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Verify access to the new PCI card.

PARTS NOTE:

REFERENCE INFORMATION:
Sun Fire x4600 and Sun Fire x4600 M2 Servers Service Manual
http://download.oracle.com/docs/cd/E19121-01/



Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback