Asset ID: |
1-71-1313179.1 |
Update Date: | 2012-04-27 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1313179.1
:
CAM - How to Remove and Replace Midrange Disk 6540 Battery:ATR:2395:0
Related Items |
- Sun Storage Flexline 380 Array
- Sun Storage 6540 Array
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: DISK-CAP VCAP
|
In this Document
Applies to:
Sun Storage 6540 Array - Version Not Applicable to Not Applicable [Release N/A]
Sun Storage Flexline 380 Array - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Goal
How to Remove and replace Midrange Disk 6540 Battery CAM
Fix
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Has gone through basic 2500/6000 Array Hardware Introduction
Common Array Manager
DELIVERY REQUIREMENT: For immediate delivery within contractual terms.
FIELD ENGINEER INSTRUCTIONS
PROBLEM OVERVIEW:
One or both Write Cache Batteries have been determined as failed or nearing expiration, by the system.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Using CAM, preferably the customer's instance, confirm the existence of a Battery Nearing Expiration, Expiration, or Battery Failed fault.
2. Follow the Battery Removal and Replacement instructions in the CAM Service Advisor(SA) for the array.
NOTE: There are instructions in the SA that state not to remove the battery if the Blue LED on the battery is NOT LIT. If you have a battery nearing expiration fault, this
instruction can be ignored. This will not cause any damage to the system, as the batteries are hot plug.
3. Verify that the battery is charging, then repeat for the other battery.
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN
OPERATIONAL STATE:
1. Verify that the battery age has been reset for each battery replaced.
2. Verify that the alarms for battery have been removed from the alarms list
3. Notify the customer that the battery charge for each battery can take up to 14 hours before write cache is restored.
PARTS NOTE:
REFERENCE INFORMATION: The Service Advisor in CAM
NOTE: If the service advisor is not available, you may download or review a soft copy internally at:
http://pts-storage.us.oracle.com/products/CAM/SA.html
TIME ESTIMATE: 20 minutes per battery
Attachments