Asset ID: |
1-71-1310330.1 |
Update Date: | 2012-07-24 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1310330.1
:
How to Remove and Replace a Sun Enterprise 450 Hard Disk Drive:ATR:1371:1
Related Items |
- Sun Enterprise 450 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
|
In this Document
Applies to:
Sun Enterprise 450 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
********************************************************************************
To report errors or request improvements on this procedure,
please go to http://support.us.oracle.com and put a comment on Doc ID: 1310330.1
********************************************************************************
450 HDD Replacement
Fix
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
E450 Product Training or Experience
TIME ESTIMATE: 30 minutes
TASK COMPLEXITY: 1
FIELD ENGINEER INSTRUCTIONS
PROBLEM OVERVIEW: Disk fault
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup must not be a pre-requisite but is a wise precaution depending on importance of data for user.
The system's disk "hot-plug" feature lets you remove a disk drive without shutting down the operating system or turning off the system power. Then operating system should be configured by the customer such that the disk drive is free for replacement. e.g. The disk may be part of Solaris Volume Manager, Veritas Volume Manager, mounted file-system, raw partitions, etc. A data backup may be required to restore data onto a replaced disk depending on situation and customer demand.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
You must follow antistatic precautions when handling a disk drive. Attach the wrist strap to the inside bottom of the chassis, just inside the bottom door.
1) Remove HDD
1. Prepare the system for disk removal.
2. If you are not hot-plugging the disk drive, halt the operating system and turn off the system power.
3. Open the bottom door.
4. Locate the disk drive that you need to remove.
5. Slide the latch at the right of the drive handle to the right to release it.
6. Swing open the handle as far as it will go and pull on it to slide the drive out.
7. Place the drive on an antistatic mat.
################################################################################
The exact hot-plug procedure depends on which version of the Solaris operating environment you are using. For the complete procedure, please refer to admin guide for solaris version installed.
################################################################################
2) Install HDD
1. Open the bottom door.
2. Align the drive with its drive bay opening.
3. Fit the drive into the guide rails on each side of the drive bay.
4. Slide the disk drive into the drive bay until the handle contacts the disk cage.
5. Swing the drive handle closed until it latches.
6. Close the bottom door, and lock it if necessary.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Reconfigure disk as previously configured. e.g. Part of raid set or mounted file-system or raw partition or other.
PARTS NOTE:
part location
REFERENCE INFORMATION:
http://download.oracle.com/docs/cd/E19088-01/450.srvr/index.html
Attachments