Asset ID: |
1-71-1309208.1 |
Update Date: | 2012-08-01 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1309208.1
:
How to Replace the Sun Blade X6250 Memory Modules:ATR:2617:0
Related Items |
- Sun Blade 6000 System
- Sun Blade X6250 Server Module
- Sun Blade 6048 System
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Blade X6250 Server Module - Version Not Applicable and later
Sun Blade 6000 System - Version Not Applicable and later
Sun Blade 6048 System - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Replace the Sun Blade X6250 Memory Modules.
Fix
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
A DIMM is a CRU and can be replaced by anyone.
TIME ESTIMATE: 60 minutes
TASK COMPLEXITY: 0
FIELD ENGINEER INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?:
System must be shut down.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1.- Power off the server and remove the server module from the chassis
2.- Remove the main cover.
3.- Press the fault remind button on the motherboard to illuminate the LED for the DIMMs that have failed.
4.- Locate the DIMM slot on the motherboard to which you will install a DIMM.
5.- To remove a DIMM:
* Rotate both DIMM slot ejectors outward as far as they will go.
* Carefully lift the DIMM straight up to remove it from the socket.
6.- To install a DIMM:
* Ensure that the DIMM slot ejectors at each end of the memory socket are fully open (rotated outward) to accept the new DIMM.
* Align the notch in the bottom edge of the DIMM with the key in the DIMM socket.
* Press down evenly on both top corners of the DIMM until the ejectors snap over the cutouts in the left and right edges of the DIMM.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Restart the system
PARTS NOTE:
Parts not needed
REFERENCE INFORMATION:
http://download.oracle.com/docs/cd/E19045-01/
Attachments
This solution has no attachment