Asset ID: |
1-71-1309183.1 |
Update Date: | 2012-08-01 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1309183.1
:
How to Replace the Sun Blade X6250 REM Battery:ATR:2620:0
Related Items |
- Sun Blade 6000 System
- Sun Blade X6250 Server Module
- Sun Blade 6048 System
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Blade X6250 Server Module - Version Not Applicable and later
Sun Blade 6000 System - Version Not Applicable and later
Sun Blade 6048 System - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Replace the Sun Blade X6250 REM Battery.
Fix
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
This component is a CRU and can be replaced by anyone.
DELIVERY REQUIREMENT:
This operation requires a complete power outage of the entire machine.
TIME ESTIMATE: 30 minutes
FIELD ENGINEER INSTRUCTIONS
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
Shut down the server
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1.- Power off the server and remove the server module from the chassis.
2.- Remove the main cover.
3.- Remove the Sun Blade RAID 5 Expansion Module, as described here: https://sunspace.sfbay.sun.com/display/STOTSCSTQ/X6250+RAID+Expansion+Module
4.- Remove the battery
* Turn the Sun Blade REM board over. (The battery is located underneath the REM board)
* Disconnect the battery cable from the Sun Blade REM
* Remove the four screws that secure the battery to the Sun Blade REM board
* Note the polarity of the battery as you will need to put the new battery in with the same polarity.
* Lift the battery away from the Sun Blade REM board
5.- Install the new battery:
* Attach the battery to the Sun Blade REM using the four screws
* Connect the cable on the battery to the connector on the Sun Blade REM
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Restart the server
PARTS NOTE:
No parts needed.
REFERENCE INFORMATION:
http://download.oracle.com/docs/cd/E19045-01/
Attachments
This solution has no attachment