Asset ID: |
1-71-1309096.1 |
Update Date: | 2012-09-21 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1309096.1
:
SL500/SL3000/SL8500 - Process to determine Current Microcode Version on Library
Related Items |
- Sun StorageTek SL3000 Modular Library System
- Sun StorageTek SL500 Modular Library System
- Sun StorageTek SL8500 Modular Library System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL500 Library
|
In this Document
Applies to:
Sun StorageTek SL3000 Modular Library System - Version Not Applicable and later
Sun StorageTek SL500 Modular Library System - Version Not Applicable and later
Sun StorageTek SL8500 Modular Library System - Version Not Applicable and later
Information in this document applies to any platform.
Checked for relevance on 21-Sept-2012.
Goal
The purpose of this document is to show how to determine what is the current version that is running in the libraries SL500, SL3000 or SL8500.
Fix
Through SLConsole:
- The first step is to log into SL Console.
- Once logged in, select Library, in the main root. (i.e Library 1,0,0,0,0).
- When the Library is selected, choose in the Toolbar 'System Detail'.
- Then choose the tab 'Properties'.
- Then pick the sub-tab 'Library Controller'.
- Under 'Code Version' box you will find the version of the current microcode.
Through SSH:
If you do not have access to SL Console, you can also obtain the current version via console command.
- The first step is to connect to the library through SSH.
- Execute the command; version print <device address> i.e SL8500> version print 1,0,0,0,0
- A list will be displayed with all library controller versions, same information listed through SL Console.
Attachments