Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1309042.1
Update Date:2012-08-08
Keywords:

Solution Type  Technical Instruction Sure

Solution  1309042.1 :   How to Replace the Fabric Expansion Module for the Sun Blade X6450:ATR:2606:0  


Related Items
  • Sun Blade X6450 Server Module
  •  
  • Sun Blade 6000 System
  •  
  • Sun Blade 6048 System
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Fix


Applies to:

Sun Blade X6450 Server Module - Version Not Applicable and later
Sun Blade 6000 System - Version Not Applicable and later
Sun Blade 6048 System - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to Replace the Fabric Expansion Module for the Sun Blade X6450.

Fix

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)
Field engineer experience.

DELIVERY REQUIREMENT:
As required by the customer.

TIME ESTIMATE: 60 minutes

FIELD ENGINEER INSTRUCTIONS

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :Power off the server and remove the server module from the chassis.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

To remove
1. Remove the main cover

2. Remove the protective cap from the fabric expansion module connector (located on the left side of the center support bracket)

3. Position the fabric expansion module (connector side down) over the fabric expansion module connector on the motherboard, and insert the (opposite) edge of the fabric expansion module into the slots on the center support bracket.

To install

1. Repeat step 1,2 and 3, describe above.

2. Gently press the connector on the underside of the fabric expansion module onto the connector on the motherboard, until the edge of the board is secured by the ejector clip on the left-side support bracket.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Start up the system.

PARTS NOTE:

REFERENCE INFORMATION:
http://download.oracle.com/docs/cd/E19045-01/blade.x6450/index.html


Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.