Solution Type  Technical Instruction Sure

Solution  1307350.1 :   How to Remove and Replace a T5140/T5240 System Board Battery:ATR:1328:0  


Related Items
  • Sun SPARC Enterprise T5240 Server
  •  
  • Sun SPARC Enterprise T5140 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
  Goal
  Solution


Applies to:

Sun SPARC Enterprise T5240 Server - Version: Not Applicable and later   [Release: N/A and later ]
Sun SPARC Enterprise T5140 Server - Version: Not Applicable and later    [Release: N/A and later]
Information in this document applies to any platform.

Goal

How to remove and replace a T5140/T5240 System Board Battery

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)

Nothing beyond basic partner training to be qualified as a Sun Service Delivery Partner is required.

TIME ESTIMATE: 60 minutes

Task Complexity: 0

FIELD ENGINEER INSTRUCTIONS

PROBLEM OVERVIEW:

System Board Battery Failure

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

The customer should conduct an orderly software system shutdown. Then power down the system and disconnect the Power Cord.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

1) Remove a Battery

1. Remove PCIe/XAUI riser 2.

2. Using a No. 1 flat-blade screwdriver, press the latch and remove the battery from the motherboard.

2) Install a Battery

1. Unpack the replacement battery.

2. Pry the clip open slightly and insert the battery into the battery holder.

3. Install PCIe/XAUI riser 2.

4. Use the ILOM setdate command to set the day and time.

5. After returning the server to operation, check and reset the Solaris OS date.

OBTAIN CUSTOMER ACCEPTANCE

PARTS NOTE:

Part location

REFERENCE INFORMATION:

Sun SPARC Enterprise T5140 and T5240 Servers Service Manual
http://download.oracle.com/docs/cd/E19910-01/820-3318-14/820-3318-14.pdf