![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1307312.1 : How to Remove and Replace a T5140/T5240 Power Supply:ATR:1322:0 [VIDEO]
In this Document
Applies to:Sun SPARC Enterprise T5140 Server - Version: Not ApplicableSun SPARC Enterprise T5240 Server - Version: Not Applicable and later [Release: N/A and later] Information in this document applies to any platform. GoalHow to remove and replace a T5240 Power Suppy (FRU)SolutionDISPATCH INSTRUCTIONSWHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?) Minimal field experience customer replaceable component TIME ESTIMATE: 30 minutes Task Complexity: 0 NOTE: Never replace a 2nd Edition PSU with a 1st Edition PSU. For more information, please refer to the appropriate product in the Sun System Handbook here: https://support.us.oracle.com/handbook_internal/index.html 2nd Edition PSUs will include "2nd Edition" in the part description, "1st Edition" will not. FIELD ENGINEER INSTRUCTIONS WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : Hot swappable component normal system recovery protection recommended. WHAT ACTION DOES THE ENGINEER NEED TO TAKE: Follow standard ESD precautions Replace failed power supply. Power supply zero is lower slot. Power supply one is in the upper slot. Reference procedure in Sun SPARC Enterprise T5140 and T5240 Servers Service Manual OBTAIN CUSTOMER ACCEPTANCE PARTS NOTE:REFERENCE INFORMATION: http://download.oracle.com/docs/cd/E19712-01/index.html Attachments This solution has no attachment |
||||||||||||
|