Solution Type  Technical Instruction Sure

Solution  1307296.1 :   How to Replace a T5140/T5240 or Netra T5440 Memory DIMM:ATR:1318:0  


Related Items
  • Sun Netra T5440 Server
  •  
  • Sun SPARC Enterprise T5240 Server
  •  
  • Sun SPARC Enterprise T5140 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




Applies to:

Sun SPARC Enterprise T5240 Server - Version Not Applicable and later
Sun SPARC Enterprise T5140 Server - Version Not Applicable and later
Sun Netra T5440 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

********************************************************************************
To report errors or request improvements on this procedure,
please put a comment on Doc ID: 1307296.1
********************************************************************************

How to remove and replace a T5140/T5240 or Netra T5440 Memory DIMM

Fix

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE ENGINEER NEED:
T5140/T5240 or Netra Product Training

TIME ESTIMATE: 60 minutes

TASK COMPLEXITY: 0

FIELD ENGINEER INSTRUCTIONS

PROBLEM OVERVIEW:  Memory/DIMM Failure

WHAT STATE SHOULD SYSTEM BE IN TO BE READY TO PERFORM RESOLUTION ACTIVITY?
A data backup is not a pre-requisite but is a wise precaution. The customer should conduct an orderly software system shutdown. Then power down system and disconnect Power Cord

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Boot system and monitor boot sequence for errors. Test functionality of system:
1. Run the Solaris "fmadm faulty" and SP/ILOM "show faulty" command (if only ALOM is supported run "showfaults -v" command) to verify that the fault has been cleared.
2. Perform one of the following tasks based on your verification results:
   * If the previous steps did not clear the fault, refer to doc 1004229.1 for information about the tools and methods you can use to diagnose and clear component faults.
   * If the previous steps indicate that no faults have been detected, then the component has been replaced successfully. No further action is required
3. Restart software applications per applicable administration guides to resume system operation.

PARTS NOTE: Netra: https://support.oracle.com/handbook_private/Systems/Netra_T5440/components.html#Memory

REFERENCE INFORMATION:
T5140:  http://download.oracle.com/docs/cd/E19712-01/

T5240: http://download.oracle.com/docs/cd/E19910-01/

Netra T5440: http://docs.oracle.com/cd/E19874-01/index.html