![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1307048.1 : How to Remove and Replace a T5140/T5240 XAUI Card:ATR:1311:0
In this Document
Applies to:Sun SPARC Enterprise T5240 Server - Version: Not Applicable to Not Applicable - Release: N/A to N/ASun SPARC Enterprise T5140 Server - Version: Not Applicable and later ] Information in this document applies to any platform. GoalHow to remove and replace a T5140/T5240 XAUI CardSolutionDISPATCH INSTRUCTIONSWHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?) T5240 Product training and/or sufficient field support experience. TIME ESTIMATE: 120 minutes Task Complexity: 0 FIELD ENGINEER INSTRUCTIONS PROBLEM OVERVIEW: XAUI network card replacement. WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : Full verified backups of all data and operating systems potentially affected by service activities The system needs to be shut down and powered off with power cables disconnected. WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: Boot system and verify all network connectivity. PARTS NOTE: Single 10-Gigabit Ethernet XAUI Adapter https://support.oracle.com/handbook_private/Devices/Ethernet/ETHER_XAUI_Single_10GigE.html 10Gb/sec XFP Optical Transceiver Short Range (SR) 10Gb/sec XFP Optical Transceiver Long Range (LR) https://support.oracle.com/handbook_private/Devices/Ethernet/ETHER_PCIX_XFP_Opt_Trnscvr.html REFERENCE INFORMATION: T5140 manual: http://download.oracle.com/docs/cd/E19712-01/ T5240 manual: http://download.oracle.com/docs/cd/E19910-01/ Attachments This solution has no attachment |
||||||||||||
|