![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 1307035.1 : How to Remove and T5140/T5240 Power Cord Kit:ATR:1302:0
In this Document
Applies to:Sun SPARC Enterprise T5240 Server - Version: Not Applicable to Not Applicable - Release: N/A to N/ASun SPARC Enterprise T5140 Server - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Information in this document applies to any platform. GoalHow to remove and replace a T5140/T5240 power cord kitSolutionDISPATCH INSTRUCTIONS WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?) T5140/T5240 Training TIME ESTIMATE: 30 minutes Task Complexity: 0 FIELD ENGINEER INSTRUCTIONS PROBLEM OVERVIEW: Power Cord Replacement WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : With redundant power there is no need to take additional steps. WHAT ACTION DOES THE ENGINEER NEED TO TAKE: Follow standard ESD precautions. Identify defective cord and replace it. OBTAIN CUSTOMER ACCEPTANCE PARTS NOTE: REFERENCE INFORMATION: T5140 manual: http://download.oracle.com/docs/cd/E19712-01/ T5240 manual: http://download.oracle.com/docs/cd/E19910-01/ Attachments This solution has no attachment |
||||||||||||
|