Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1307028.1
Update Date:2012-08-24
Keywords:

Solution Type  Technical Instruction Sure

Solution  1307028.1 :   How to Remove and Replace a T5140/T5240 PCI Card:ATR:1304:0  


Related Items
  • Sun SPARC Enterprise T5140 Server
  •  
  • Sun SPARC Enterprise T5240 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
Goal
Fix


Applies to:

Sun SPARC Enterprise T5240 Server - Version Not Applicable to Not Applicable [Release N/A]
Sun SPARC Enterprise T5140 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Goal

How to remove and replace a T5240 PCI card (CRU)

***********************************************************
To report errors or request improvements on this procedure,
please Add a Comment on Doc ID: 1307028.1
***********************************************************

Fix

*DISPATCH INSTRUCTIONS*

WHAT SKILLS DOES THE ENGINEER NEED:(IS A SITE ENGINEER AVAILABLE?)

Nothing beyond basic partner training to be qualified as a Sun Service Delivery Partner

TIME ESTIMATE: 30 minutes

Task Complexity: 0

*FIELD ENGINEER INSTRUCTIONS*

PROBLEM OVERVIEW:

PCIe/XAUI card failure

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a pre-requisite but is a wise precaution.

System needs to be shutdown by customer

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

Boot system and monitor boot sequence for errors. Test functionality of system:
1. Run the Solaris "fmadm faulty" and SP/ILOM "show faulty" command (if only ALOM is supported run "showfaults -v" command) to verify that the fault has been cleared.
2. Perform one of the following tasks based on your verification results:
   * If the previous steps did not clear the fault, refer to doc 1004229.1 for information about the tools and methods you can use to diagnose and clear component faults.
   * If the previous steps indicate that no faults have been detected, then the component has been replaced successfully. No further action is required
3. Restart software applications per applicable administration guides to resume system operation.

NOTE: Customer might need to consult the PCIe/XAUI card specific manual for procedure to bring the card into operation

PARTS NOTES:

N/A

REFERENCE INFORMATION:
T5140 manual: http://download.oracle.com/docs/cd/E19712-01/
T5240 manual: http://download.oracle.com/docs/cd/E19910-01/


Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback