Solution Type Technical Instruction Sure Solution 1296952.1 : SL3000/SL500 - Will The WWNN Remain the Same After an MPU2 to PUA Upgrade?
In this Document
Applies to:Sun StorageTek SL500 Modular Library System - Version Not Applicable and laterSun StorageTek SL3000 Modular Library System - Version Not Applicable and later Information in this document applies to any platform. GoalWill the WWNN remain the same after an MPU2 to PUA upgrade? Also, will the WWPN remain the same for Port1 and will the WWPN for Port2 increment by some value over the value of Port1? Conversion Bill / Instructions FixThe WWNN / WWPN values are derived by the seed value on the PUK card. Therefore, when changing the MPU2 card to a PUA/PUA2 card the WWNN will be the same as the MPU2 card. The WWPN will remain the same for port 1. For the second port, it depends on if the card is a PUA or a PUA2. PUA will increment by 2, PUA2 will increment by 1. Attachments This solution has no attachment |
||||||||||||||
|