Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1270963.1
Update Date:2011-11-17
Keywords:

Solution Type  Technical Instruction Sure

Solution  1270963.1 :   How to Remove and Replace a System Configuration Card for a Sun Fire V240:ATR:749:0 [Video]  


Related Items
  • Sun Fire V240 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  




In this Document
  Goal
  Solution


Applies to:

Sun Fire V240 Server - Version: Not Applicable to Not Applicable - Release: N/A to N/A
Information in this document applies to any platform.

Goal

Video - Sun Fire V240 Action Plan: System Configuration Card Replacement (2:15)

Solution

DISPATCH INSTRUCTIONS:

WHAT SKILLS DOES THE ENGINEER NEED:
Nothing beyond basic V210/V240 server training

TIME ESTIMATE: 30 minutes

TASK COMPLEXITY: 0


FIELD ENGINEER INSTRUCTIONS:

PROBLEM OVERVIEW:
Configuration Card Failed

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

WHAT ACTION NEEDS TO BE TAKEN:

Ensure that the system configuration card is not removed before system is brought down.

Follow standard ESD procedures to avoid Electrostatic Discharge

Replace the part following the steps below, refererence the service manual below:

Remove the defective part:

1.Power off the server.
2.Ensure that the server is properly grounded.
3.Remove the front section of the cover assembly.
4.Remove the system configuration card.

Install the new part:

1.Install the system configuration card.

2. Replace the front cover assembly section

3. Power on the server.

OBTAIN CUSTOMER ACCEPTANCE:

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Restart software applications per applicable administration guides to resume system operation.

PARTS NOTE: Refer to the System Handbook

REFERENCE INFORMATION: Sun Fire V210/V240 Service Manual:
http://download.oracle.com/docs/cd/E19088-01/v240.srvr/index.html


Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.