Asset ID: |
1-71-1020381.1 |
Update Date: | 2012-04-16 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1020381.1
:
SL8500/3000 - Need to Set Time/Date on SL Console
Related Items |
- Sun StorageTek SL3000 Modular Library System
- Sun StorageTek SL8500 Modular Library System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
|
PreviouslyPublishedAs
257229
Applies to:
Sun StorageTek SL3000 Modular Library System - Version Not Applicable and later
Sun StorageTek SL8500 Modular Library System - Version Not Applicable and later
All Platforms
Checked for relevance on 16-Apr-2012.
Goal
Need to Set Time/Date on SL Console.
Fix
Steps to Follow
The time and date inthe local SL Console is set from the PC BIOS.
To change the time or date, one needs to connect to the SL Console with a keyboard. During the boot process, activate the BIOS menus. At this point, you can change the time and date.
The CLI command for time and date only sets the HBC cards time and date. It has no effect on the SL Console.
When reports are pulled, the time stamp on the data is from the HBC time regardless to what the SL Console time and date are set to.
Attachments
This solution has no attachment