Solution Type Technical Instruction Sure Solution 1020177.1 : ACSLS - Configuration Utility Fails When the SL500 Base Module CAP is Configured for Storage
PreviouslyPublishedAs 253648
Applies to:Sun StorageTek SL500 Modular Library SystemSun StorageTek Auto Cartridge Sys Lib SW (ACSLS) - Version: 7.3 and later [Release: 7.0 and later] All Platforms Checked for relevance on 29- Nov-2011. GoalDescriptionThe ACSLS configuration utility will fail with a timeout error if the SL500 base module CAP is configured for use as storage cells. The SL500 base module CAP should always be configured for use as I/O cells to enable Enter and Eject operations. SL500 expansion modules may be configured for use as storage or I/O cells. There may also be errors in the postgres logs relating to the size of the cap, for example: ERROR: new row for relation "captable" violates check constraint "captable_cap_size_check" To confirm cap size values the following command can be issued: $ psql -d acsdb Welcome to psql 8.1.11, the PostgreSQL interactive terminal. Type: \copyright for distribution terms \h for help with SQL commands \? for help with psql commands \g or terminate with semicolon to execute query \q to quit acsdb=> \d captable Table "acsss.captable" Column | Type | Modifiers -------------------+---------+-------------------- acs | integer | not null default 0 lsm | integer | not null default 0 cap | integer | not null default 0 cap_status | integer | not null default 0 cap_priority | integer | not null default 0 cap_state | integer | not null default 0 cap_mode | integer | not null default 0 cap_size | integer | not null default 0 cap_condition | integer | not null default 0 cap_availability | integer | not null default 0 cap_desired_state | integer | not null default 7 Indexes: "captable_pkey" PRIMARY KEY, btree (acs, lsm, cap) Check constraints: "captable_acs_check" CHECK (acs >= 0 AND acs <= 31) "captable_cap_availability_check" CHECK (cap_availability > -1 AND cap_availability < 5) "captable_cap_check" CHECK (cap >= 0 AND cap <= 11) "captable_cap_condition_check" CHECK (cap_condition > 0 AND cap_condition < 4) "captable_cap_desired_state_check" CHECK (cap_desired_state = 7 OR cap_desired_state = 5 OR cap_desired_state = 2) "captable_cap_mode_check" CHECK (cap_mode = 1 OR cap_mode = 2) "captable_cap_priority_check" CHECK (cap_priority >= 0 AND cap_priority <= 16) "captable_cap_size_check" CHECK (cap_size > 0) "captable_cap_state_check" CHECK (cap_state = 7 OR cap_state = 5 OR cap_state = 6 OR cap_state = 8 OR cap_state = 2) "captable_cap_status_check" CHECK (cap_status = 7 OR cap_status = 10 OR cap_status = 34 OR cap_status = 35 OR cap_status = 151) "captable_lsm_check" CHECK (lsm >= 0 AND lsm <= 126) SolutionSteps to Follow This problem only affects the SL500 base module. 1. Verify that the acsss_config utility fails with these error messages: This step builds a database image of your complete library hardware configuration. Before proceeding, make sure that your library is completely configured, that all subsystems are functional and powered on. Build/Verify library configuration? (y or n): y /export/home/ACSSS/config/in_lib_conf: Time-out awaiting library handler response /export/home/ACSSS/config/in_lib_conf: Cannot get LH data /export/home/ACSSS/config/in_lib_conf: Failed to configure LSMs 2008-11-07 12:36:50 791 N in_tbl_dest.c 1 120 The following tables have been removed: acstable,audittable, captable,celltable,csitable,drivetable,lockidtable, lsmtable,paneltable,pooltable,portable,vactable,scr_distr_table,volumetable, clienttable,ptptable,handtable,lmutable,displaycommand,displayoptions, displayfields,displayoptval,displaysubfields lib_config.sh 1612: Error: Configuration command in_lib_conf failed. Exiting. 2. Verify from the Sun Field Engineer how the CAP of the SL500 base module is configured If the CAP is configured for use as I/O, there could be other problems causing the acsss_config to fail. Refer to Document: 1020074.1 Communications Configuration If the CAP is configured for use as storage, ask the Sun Field Engineer to change the CAP to be used for I/O. This is usually done using the SL500 CLI utility and not through ACSLS. Run the acsss_config utility again after making the CAP attribute change. Attachments This solution has no attachment |
||||||||||||
|