Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1020023.1
Update Date:2011-12-14
Keywords:

Solution Type  Technical Instruction Sure

Solution  1020023.1 :   9x40/T10000 - Process for New Drive Installation or Replacement  


Related Items
  • Sun StorageTek 9840D Tape Drive
  •  
  • Sun StorageTek T10000A Tape Drive
  •  
  • Sun StorageTek 9840 Tape Drive
  •  
  • Sun StorageTek T10000B Tape Drive
  •  
  • Sun StorageTek 9840B Tape Drive
  •  
  • Sun StorageTek 9940B Tape Drive
  •  
  • Sun StorageTek 9940 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  
  • .Old GCS Categories>Sun Microsystems>Storage - Tape>Drives - 9840
  •  
  • .Old GCS Categories>Sun Microsystems>Storage - Tape>Drives - 9940
  •  

PreviouslyPublishedAs
251026


Applies to:

Sun StorageTek 9840B Tape Drive - Version: Not Applicable and later   [Release: N/A and later ]
Sun StorageTek 9840 Tape Drive - Version: Not Applicable and later    [Release: N/A and later]
Sun StorageTek 9840D Tape Drive - Version: Not Applicable and later    [Release: N/A and later]
Sun StorageTek 9940 Tape Drive - Version: Not Applicable and later    [Release: N/A and later]
Sun StorageTek 9940B Tape Drive - Version: Not Applicable and later    [Release: N/A and later]
All Platforms
Checked for relevance on 13-Dec-2011.

Goal

New Drive Installation or Drive Replacement Process in SLxxxx libraries.
When a new drive is installed (new installs into new slots ) it is important that the following process be used to avoid issues where the drive is not recognized by the switch due to two different WWN's in play in the drive.

Solution

Steps to Follow
Take the following actions when installing new or replacement tape drives:
When the drive is first powered up it will login to the switch with the factory set WWN.  After the drive communicates with the library, the WWN will be changed to a library generated dynamic WWN.  When the drive tries to communicate with the switch with the dynamic WWN, the switch will not respond and vice versa.

1. Install the drive in the library slot. Ensure that the data path cable is disconnected from the drive at this time.
2. Bring up the drive and wait until the library status shows the drive status as green.
3. Plug in the data path cable to the drive. The drive should login to the switch with the dynamic WWN given to it by the library.

Notes:
This applies to 9x40 and T10K drives installed in libraries that use a dynamic WWN such as SL3000 and SL8500.

Once this process is done the first time, the drive remembers the dynamic library WWN from that point forward for the life of that drive in that particular library slot.