![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Solution Type Technical Instruction Sure Solution 1019730.1 : Sun SPARC(R) Enterprise M3000 and M3000-E (SPARC VII+) Server Device Paths
PreviouslyPublishedAs 244806
Applies to:Sun SPARC Enterprise M3000 ServerAll Platforms Goalhow the Sun SPARC Enterprise(R) M3000 and M3000-E (SPARC64 VII+) system device paths are arrangedSolutionDescriptionThe intent of this document is to provide the reader with an overview of how the Sun SPARC Enterprise(R) M3000 and M3000-E (SPARC64 VII+) system device paths are arranged. Steps to Follow - NEW => M3000-E (SPARC64 VII+) |----- /pci@0,600000/pci@0 (Base Path) |-- ../pci@0/scsi@0/disk0 (sd@0,0) HD0 |-- ../pci@0/scsi@0/disk1 (sd@0,1) HD1 |-- ../pci@0/scsi@0/disk2 (sd@0,2) HD2 |-- ../pci@0/scsi@0/disk3 (sd@0,3) HD3 |-- ../pci@0/scsi@0/disk4 (sd@4,0) DVD |-- ../pci@0/scsi@0/0/0/xx@5,z, SAS port |-- ../pci@1/network@0 BGE0 |-- ../pci@1/network@0,1 BGE1 |-- ../pci@2/network@0 BGE2 |-- ../pci@2/network@0,1 BGE3 |-- ../pci@8 Slot 0 (PCIe) |----- /pci@1,700000/pci@0/pci@0 Slot 1 (PCIe) |----- /pci@1,700000/pci@0/pci@8 Slot 2 (PCIe) |----- /pci@1,700000/pci@0/pci@9 Slot 3 (PCIe)
IMPORTANT NOTE: CHECK following Doc to verify XCP version and patches for SPARC VII+
=> M3000 The following is a graphical representation of the Sun SPARC Enterprise M3000 device path layout: |----- /pci@0,600000/pci@0 (Base Path) |-- ../pci@0/scsi@0/disk0 HD0 |-- ../pci@0/scsi@0/disk1 HD1 |-- ../pci@0/scsi@0/disk2 HD2 |-- ../pci@0/scsi@0/disk3 HD3 |-- ../pci@0/scsi@0/disk4 DVD |-- ../pci@0/scsi@0/disk5 or 6 SAS port |-- ..pci@1/pci@0/network@4 BGE0 |-- ..pci@1/pci@0/network@4,1 BGE1 |-- ..pci@2/pci@0/network@4 BGE2 |-- ..pci@2/pci@0/network@4,1 BGE3 |-- ..pci@8 Slot 0 (PCIe) |----- /pci@1,700000/pci@0/pci@0 Slot 1 (PCIe) |----- /pci@1,700000/pci@0/pci@8 Slot 2 (PCIe) |----- /pci@1,700000/pci@0/pci@9 Slot 3 (PCIe)
For more information on Sun SPARC Enterprise M8000/M9000
device paths, see Technical Instruction < Solution: 205724 > Sun SPARC Enterprise M8000 and M9000 Device Paths. For more information on Sun SPARC Enterprise M4000/M5000 device paths, see Technical Instruction < Solution: 203831 > Sun SPARC Enterprise M4000 and M5000 Device Paths. For more information on External I/O Expansion Unit device
paths, see Technical Instruction < Solution: 207442 > Sun SPARC External I/O Expansion Unit Device Paths. Actual device paths may be seen using some of the following methods: OBP: show-devs command Solaris: /etc/path_to_inst file Solaris: prtpicl command Solaris: prtdiag -v command Internal CommentsThis document contains normalized content and is managed by the the Domain Engineer(s) of the respective domains. This document references external documents which are also available internally as: Technical Instruction - < Document 1011446.1 > -Enterprise Mx000 Servers Logical System Board (LSB) Technical Instruction - < Document 1004116.1 > -Sun SPARC Enterprise M8000 and M9000 Device Paths Technical Instruction - < Document 1002807.1 > -Sun SPARC Enterprise M4000 and M5000 Device Paths Technical Instrustion - < Document 1005332.1 > -Sun SPARC External I/O Expansion Unit Device Paths. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the Document Feedback alias(es) listed below:
Date: 2010-05-04 User: Cootware Action: Tech Review changes Comment: Link is corrected. Content is valid M3000, OPL, Device Paths, Normalized Attachments This solution has no attachment |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|