Solution Type Technical Instruction Sure Solution 1019066.1 : Sun Fire[TM] v1280, 3800, 4800, 4810, 6800, E2900, E4900, E6900 and Netra[TM] 1280, 2900 servers: How to collect scextended or 1280extended Explorer
PreviouslyPublishedAs 234161 Applies to:Sun Fire 6800 Server - Version Not Applicable and laterSun Fire 4810 Server - Version Not Applicable and later Sun Fire E2900 Server - Version Not Applicable and later Sun Fire E4900 Server - Version Not Applicable and later Sun Netra 1290 Server - Version Not Applicable and later All Platforms GoalThis document describes how to run an scextended or 1280extended Explorer on Sun Fire[TM] v1280, 3800, 4800, 4810, 6800, E2900, E4900, E6900 and Netra[TM] 1280, 1290 servers.
Available for this topic, a Video Tutorial; Brief how-to video tutorials that provide step-by-step instructions answering some of the most frequently asked questions. View the video answer and/or follow the detailed instructions below. Running scextended or 1280extended Explorer on a Sun Fire system controller will collect information from the System Controller(s). The SC has access to the hardware level error and configuration information. The SC has a limited amount of memory to store logs, the logs are lost if the SC is rebooted or power cycled. NOTES: FixFor 3800, 4800, 4810, 6800, E4900, E6900 servers, follow the procedure below:1) As "root" from a system with telnet or ssh access to the SC(s); Preferably the loghost:
2) When the explorer reaches the scextended module you will be asked to enter the hostname of the SC, similar to the following example:
3) You will then be required to enter the system controller password.
4) Once the data collection has completed for that SC you will be prompted to enter the name of the next SC.
5) If you need to collect data from a larger number of SCs this can be done from a single explorer by adding the SC hostnames and passwords to /etc/opt/SUNWexplo/scinput.txt
For v1280, E2900, n1280, or n1290 server, follow the procedure below:The scextended option in Explorer software does NOT work for these servers because the mechanism used to access the 1280/1290/E2900 system controller is different. Beginning with Sun Explorer 5.0, a new module was added to collect information from these system controllers - The 1280extended module. 1280extended requires the ability to connect to the system console over the network. The information collected by 1280extended is somewhat different than scextended due to the architectural differences between the platforms. From the command line run the following command as "root" :
The latest version of explorer can be downloaded from Document 1312847.1 Sun Explorer Product Information Center. Please make sure it is current (version 6.x is "current").
To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in an appropriate My Oracle Support Community - Oracle Sun Technologies Community. References<NOTE:1008676.1> - 'Best Practices' and configuring loghost on Sun Fire[TM] 3800,4800,4900,6800, and E6900 servers [Video]<NOTE:778.1> - Multimedia Content Reference Attachments This solution has no attachment |
||||||||||||
|