Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1018764.1
Update Date:2012-07-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1018764.1 :   Sun Fire[TM] Servers: 12K/15K/E25K/E20K: Cheat Sheet: SMS Command Privileges  


Related Items
  • Sun Fire E25K Server
  •  
  • Sun Fire E20K Server
  •  
  • Sun Fire 12K Server
  •  
  • Sun Fire 15K Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: SF-Exxk
  •  
  • .Old GCS Categories>Sun Microsystems>Servers>High-End Servers
  •  

PreviouslyPublishedAs
230492


Applies to:

Sun Fire 12K Server
Sun Fire 15K Server
Sun Fire E20K Server
Sun Fire E25K Server
All Platforms

Goal

The purpose of this document is to detail the permissions required for the various SMS command line interfaces.

Solution

Administration tasks on Sun Fire[TM] 12K/15K/E25K/E20K are divided and secured by group permissions. There are five SMS user role defined:
  • Platform Administrator (platadmn)
  • Platform Operator (platoper)
  • Domain Administrator (dmnXadmn)
  • Domain Configurator (dmnXrcfg)
  • Platform Servicer (platsvc)
For the domain user roles, a user group is defined for each domain A-R. root also is permitted to run a small subset of commands.
The table below details which SMS commands are available to each user role.
|                  | Plat. | Plat. | Domain | Domain | Plat. |      |
| Command | Oper. | Admin | Admin | Conf | Serv. | root |
+------------------+-------+-------+--------+--------+-------+------+
| addboard (2) | no | yes | yes | yes | no | no |
| addcodlicense | no | yes | no | no | no | no |
| addtag | no | yes | no | no | no | no |
| audithotspares | yes | yes | no | no | yes | no |
| cancelcmdsync | yes | yes | no | no | yes | no |
| checkcodlog | no | no | no | no | yes | no |
| codcheck | no | no | no | no | yes | no |
| codlogrotate | no | no | no | no | yes | no |
| codsendlog | no | no | no | no | yes | no |
| console | no | no | yes (1)| no | no | no |
| deleteboard | no | yes(3)| yes (1)| yes (1)| no | no |
| deletecodlicense | no | yes | no | no | no | no |
| deletetag | no | yes | no | no | no | no |
| disablecomponent | no | yes | yes (1)| yes (1)| yes | no |
| enablecomponent | no | yes | yes (1)| yes (1)| yes | no |
| flashupdate | no | yes | yes (1)| no | yes | no |
| help | yes | yes | yes | yes | yes | yes |
| initcmdsync | yes | yes | no | no | yes | no |
| marginclock | no | no | no | no | yes | no |
| marginvoltage | no | no | no | no | yes | no |
| moveboard (4) | no | yes | yes | yes | no | no |
| poweron | yes | yes | yes (1)| yes (1)| yes | no |
| poweroff | yes | yes | yes (1)| yes (1)| yes | no |
| rcfgadm (5) | no | yes | yes | yes | no | no |
| reset | no | no | yes (1)| no | no | no |
| resetsc | no | yes | no | no | no | no |
| rotatecodlog | no | no | no | no | yes | no |
| runcmdsync | yes | yes | no | no | yes | no |
| savecmdsync | yes | yes | no | no | yes | no |
| savecodlog | no | no | no | no | yes | no |
| setbus | no | yes | yes (1)| yes (1)| yes | no |
| setcsn | no | yes | no | no | yes | no |
| setdatasync | yes | yes | no | no | yes | no |
| setdate | no | yes | no | no | no | no |
| setdefaults | no | no | yes (1)| no | no | no |
| setfailover | yes | yes | no | no | yes | no |
| setkeyswitch | no | no | yes (1)| no | no | no |
| setobpparams | no | no | yes (1)| no | no | no |
| setupplatform | no | yes | no | no | no | no |
| showboards | yes | yes | yes (1)| yes (1)| yes | no |
| showbus | yes | yes | yes (1)| yes (1)| yes | no |
| showcmdsync | yes | yes | no | no | yes | no |
| showcodlicense | yes | yes | no | no | no | no |
| showcodusage | yes | yes | no | no | no | no |
| showcomponent | no | yes | yes (1)| yes (1)| yes | no |
| showdatasync | yes | yes | no | no | yes | no |
| showdate | yes | yes | yes | yes | yes | yes |
| showdevices | no | no | yes (1)| yes (1)| no | no |
| showkeyswitch | yes | yes | yes (1)| yes (1)| yes | no |
| showlogs | yes(6)| yes(6)| yes (1)| yes (1)| yes(6)| no |
| showobpparams | no | no | yes (1)| no | no | no |
| showplatform | yes | yes | yes (1)| yes (1)| yes | no |
| showxirstate | no | no | yes (1)| no | no | no |
| smsbackup | no | no | no | no | no | yes |
| smsconfig | no | yes | no | no | no | no |
| smsconnectsc | no | yes | no | no | no | no |
| smsrestore | no | no | no | no | no | yes |
| smsversion | no | no | no | no | no | yes |
| sysid | no | no | no | no | yes | no |
| thermcal | no | no | no | no | yes | no |
+------------------+-------+-------+--------+--------+-------+------+

Notes:
  1. Execution against the group's respective domain only.
  2. For Platform Admin, only the assign function is permitted. Domain Admin/Conf can execute against the respective domain. If the board(s) is not already assigned to the domain, it must be in the available component list.
  3. For Platform Admin, only the unassign function is permitted and only when the board is in the assigned state (i.e., not active in a running domain)
  4. For Platform Admin, only the unassign and assign functions are permitted. unassign is only possible when the board is in the assigned state (i.e., not active in a running domain). Then, and only then, is the assign function to the destination domain possible. For Domain Admin/Conf, the user must belong to both domain groups affected. If the board is not already assigned to the destination domain, it must be in the available component list for that domain.
  5. For Platform Admin, only the assign and unassign functions are permitted. unassign is only possible when the board is in the assigned state (i.e., not active in a running domain). Domain Admin/Conf can execute against the respective domain. If the board(s) is not already assigned to the domain, it must be in the available component list.
  6. Platform logs only.

Reference the System Management Services (SMS) documentation set for more details.