Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1018592.1
Update Date:2012-07-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1018592.1 :   Sun Fire[TM] servers: PCI IOMMU TLB ERROR  


Related Items
  • Sun Fire E6900 Server
  •  
  • Sun Fire 3800 Server
  •  
  • Sun Fire 6800 Server
  •  
  • Sun Fire E4900 Server
  •  
  • Sun Fire 4800 Server
  •  
  • Sun Fire E2900 Server
  •  
  • Sun Fire V1280 Server
  •  
  • Sun Fire 4810 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Exx00
  •  
  • .Old GCS Categories>Sun Microsystems>Servers>Midrange Servers
  •  
  • .Old GCS Categories>Sun Microsystems>Servers>Midrange V and Netra Servers
  •  

PreviouslyPublishedAs
230286
PCI IOMMU TLB ERROR

Applies to:

Sun Fire 3800 Server
Sun Fire 4800 Server
Sun Fire 4810 Server
Sun Fire 6800 Server
Sun Fire E2900 Server
All Platforms

Goal

Troubleshoot PCI IOMMU TLB ERROR

Solution

Description
PCI IOMMU TLB ERROR

What action should be taken when an IOMMU TLB(Transaction Look aside Buffer)
error occurs on a Sun Fire[TM] server ?



Steps to Follow
Sun Fire[TM] servers: PCI IOMMU TLB ERROR
WARNING: pcisch3 PCI fault log start:
PCI iommu error
pcisch3: Error 1 on IOMMU TLB entry b: Context=0 not Writable not Streamable
PCI Page Size=8k Address in page c6960000
Memory: Valid not Cacheable Page Frame=0
PCI error ocurred on device #1
pcisch3(pci@19,600000): PBM AFSR=0x0.00000000dwordmask=0 bytemask=0
pcisch3(pci@19,600000): PCI primary error (0):
pcisch3(pci@19,600000): PCI secondary error (0):
pcisch3(pci@19,600000): PBM AFAR 0.00000000:
pcisch3: PCI config space CSR=0xaa0
pcisch3(pci@19,600000): PCI fault log end.
Scrubbing PCI iommu TLB entries
No fatal PCI bus error(s)

Above, is an error message from the PCI nexus driver, where device #1 has an
error logged against it, relating to an erroneous entry in the IOMMU TLB.
(Transaction look aside buffer).

The pcisch instance then called the scrubber to clear the error
inside the TLB.

This is a non-fatal error and should, if not occurring very frequently,
lead to no further action, that is, no hardware or software intervention
is needed.

However, if this starts to occur frequently, further investigation
will be required.



The following is an Internal Document, Strictly for Oracle Employees Only

See <Document 1004769.1> for an in depth discussion on this and other PCI Bus issues and theories.

The Sun Fire v1280 / Netra 1280 and the Sun Fire 2900 can experience this
issue more frequently than other systems. Please make sure that the switch
to which the system is connected, is set to Gigabit speed, and that the system
itself is also running the interfaces at Gigabit speed.

Please see CR 6217062 for more information

Previously Published As 78838



Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback