Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1018574.1
Update Date:2012-07-30
Keywords:

Solution Type  Technical Instruction Sure

Solution  1018574.1 :   StorEdge[TM] 99x0 Shadow Image and TrueCopy: Volume Statuses Explained  


Related Items
  • Sun Storage 9985 System
  •  
  • Sun Storage 9990 System
  •  
  • Sun Storage 9990V System
  •  
  • Sun Storage 9985V System
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>HighEnd Arrays>SN-DK: HDS_99xx
  •  
  • .Old GCS Categories>Sun Microsystems>Storage - Disk>Datacenter Disk
  •  

PreviouslyPublishedAs
230262


Applies to:

Sun Storage 9985 System - Version: Not Applicable and later   [Release: N/A and later ]
Sun Storage 9985V System - Version: Not Applicable and later    [Release: N/A and later]
Sun Storage 9990 System - Version: Not Applicable and later    [Release: N/A and later]
Sun Storage 9990V System - Version: Not Applicable and later    [Release: N/A and later]
All Platforms

Goal

This document will explain the states that can be seen in Shadow Image, CCI and TrueCopy configurations. It will include what these states mean, volume permissions in each state and some examples of how to transition from one state to another.

Solution


State

TrueCopy

ShadowImage

PVOL permissions

SVOL permissions

SMPL

Unpaired volume

Unpaired volume

Read/Write

Read/Write

PAIR

Paired volume.  Initial copy is complete.  Updates are processed synchronously or asynchronously

Paired volume.  Initial copy is complete.  Updates are processed asynchronously

Read/Write

Read only

COPY

In paired state, but initial copy, pairsplit, or resync operation is not complete.  Includes COPY(PD), COPY(SP) and COPY(RS) statuses below.

In paired state, but initial copy, pairsplit, or resync operation is not complete.  Includes COPY(PD), COPY(SP) and COPY(RS) statuses below.

Read/Write

Read only

COPY(PD)

(pending duplex)


Initial copy in progress.  

Read/Write

Read only

COPY(SP)

(split pending)


When steady split mode is used for pairsplit.  All pvol updates prior to pairsplit command are copied.  When updates are complete, pvol and svol are identical to the pvol when split was issued.  

Read/Write

Read only

COPY(RS)

(resync)


When a split pair is resynchronized in normal mode, only the Pvol differential data is copied to the Svol.  When PSUE pair is resync'd, the entire Pvol is copied to the Svol.  

Read/Write

Read only

COPY(RS-R)

(resync-reverse)


When a split pair is resynchronized in reverse or quick restore mode (only the Svol differential data is copied to the Pvol).

Read only

Read only

RCPY

(reverse copy)


In paired state, but reverse resync operation is in progress.

Read only

Read only

PSUS

(split)

In paired state, but updates to the Svol data are suspended due to user-requested pairsplit.  The 99x0 keeps track of Pvol and Svol updates while the pair is split.

In paired state, but updates to the Svol data are suspended due to user-requested pairsplit.  The 99x0 keeps track of Pvol and Svol updates while the pair is split to allow for a faster resync.

Read/Write

Read only

Read/Write when using write enable pairsplit option.

PSUS(SP)

(quick split pending)


Means quick split mode is selected.  Only pvol differential data is copied to the svol in the background. Pairs in this state cannot be deleted

Read/Write

Read/Write

PSUE or PFUS

(suspended)

In paired state, but updates to the Svol data are suspended due to an error condition.  The volumes in this condition are not synchronized.  PSUE is PSUS with due to an error condition.  PFUS is PSUS with reason of sidefile full.

In paired state, but updates to the Svol data are suspended due to an error condition.  When a PSUE pair is resynced, the 99x0 copies the entire Pvol to the Svol (same as initial copy).  The volumes in this condition are not synchronized.

Read/Write if no error occurs in the pvol

Read only

PDUB

Used for TrueCopy LUSE pairs only.  In paired state, but updates to one or more ldevs within the LUSE pair is SMPL or PSUE (due to some error condition).


Read/Write if no error occurs in the pvol

Read only

Command examples to transition between the states above:

Current State

Desired State

CCI Command

Operation in Storage Navigator (9900V) *1 or Remote Console (9900) *2

Transitional State

SMPL

 PAIR

paircreate

Paircreate

-Sync or Async for TrueCopy

COPY(PD)

PAIR

PSUS

pairsplit

Pairsplit

Pairsplit-r (TrueCopy)

COPY(SP) or PSUS(SP)

PAIR

PSUE

pairsplit -E

Pairsplit-E *3


PAIR

SMPL

Pairsplit -S

Pairsplit-S


PSUS or PSUE

PAIR

pairesync

Pairresync

COPY (RS)

*1 Right click on the selected LU(s)/pair(s) in the TrueCopy 'Pair Operations' tab or the Shadow Image 'Main' tab to see the available operations.

*2 Select the Shadow Image or TrueCopy option from the RMC main window.  The available operations will be seen as buttons on the right hand side of the window.

*3 The -E option is for Shadow Image only and is not normally used.



Product
Sun StorageTek 9900 ShadowImage In-System Replication
Sun StorageTek 9900 TrueCopy

shadow image, cci, 9910, 9960, 9970, 9980, hitachi, pvol, svol, p-vol, s-vol, pair, psus, psue, pdub, pfus, rcpy, smpl, paircreate, pairsplit, pairresync, copy, shadowimage, trucopy, truecopy, true copy
Previously Published As
78330

Change History
Date: 2010-04-29
User Name: eh47940
Action: consisteny tittle, object:defects

Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.