Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1017395.1
Update Date:2011-07-17
Keywords:

Solution Type  Technical Instruction Sure

Solution  1017395.1 :   VTL - Does VTL support ACSLS Volume Access Control  


Related Items
  • Sun StorageTek VTL Prime System
  •  
  • Sun StorageTek VTL Value System
  •  
  • Sun StorageTek VTL Plus Storage Appliance
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VTL
  •  
  • .Old GCS Categories>Sun Microsystems>Storage - Tape>Tape Virtualization
  •  

PreviouslyPublishedAs
228476


Applies to:

Sun StorageTek VTL Value System - Version: 1.0 - Build 1323 to 1.0 - Build 1323 - Release: 1.0 to 1.0
Sun StorageTek VTL Prime System - Version: 1.0 - Build 1813 to 1.1 - Build 2076   [Release: 1.0 to 1.0]
Sun StorageTek VTL Plus Storage Appliance - Version: 1.0 - Build 1323 to 2.0 - Build 1656   [Release: 1.0 to 2.0]
All Platforms
.
***Checked for relevance on 14-07-2011*** (dd-mm-yyyy)

Goal

This document is intended to provide information on connecting ACSLS to a Oracle VTL server

Solution


VTL does work with ACSLS Volume Access Control.
1. The VTL IP and an "access id" must be entered into the internet.addresses file.

- If VTL is in an HA configuration, use the heartbeat IP.
- VTL does not send a user id as the access id, so any name can be chosen for the ACSLS internet.addresses file. The VTL hostname is recommended to be used.

2. Use the "set owner" command to set Volume ownership using the "access id" defined above.

Also refer to the ACSLS Installation, Configuration and Administration Guide (ICAG) for detailed instructions on configuring a client host for Volume Access Control