Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1017188.1
Update Date:2012-07-25
Keywords:

Solution Type  Technical Instruction Sure

Solution  1017188.1 :   Tape Libraries - Does Library Send More Than 6 Characters of Volser Barcode to Server?  


Related Items
  • Sun StorageTek L180 Tape Library
  •  
  • Sun StorageTek 9740 Tape Library
  •  
  • Sun StorageTek L20 Tape Library
  •  
  • Sun StorageTek 9310 Automated Cartridge System
  •  
  • Sun StorageTek 9710 Tape Library
  •  
  • Sun StorageTek L5500 Tape Library
  •  
  • Sun StorageTek L40 Tape Library
  •  
  • Sun StorageTek L700 Tape Library
  •  
  • Sun StorageTek L80 Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK Legacy Drive and Library
  •  

PreviouslyPublishedAs
228044


Applies to:

Sun StorageTek L180 Tape Library - Version Not Applicable and later
Sun StorageTek L20 Tape Library - Version Not Applicable and later
Sun StorageTek L40 Tape Library - Version Not Applicable and later
Sun StorageTek L5500 Tape Library - Version Not Applicable and later
Sun StorageTek L700 Tape Library - Version Not Applicable and later
All Platforms
Checked for relevance on 25-July-2012.

Goal

Does library send more than 6 characters of volser barcode to server?

Fix

Steps to Follow
Oracle/STK libraries only send 6 characters of the Volser label on the bus to the server.  This is working as designed. Engineering states there are NO plans to change how Volser is presented on Lxxx, Lxx, 97xx or L55/93x0 libraries.  These are legacy libraries and additional functionality is not being added according to program management.
Non Oracle/STK libraries support 8 character Volser numbers to the server.  Some customers have read that these libraries support 6 + 2 characters in the documentation.   This is in regards to internal library workings only where the library manages multiple types of media.   The last 2 characters designate the type of media inside the library.   This does not mean that the last 2 characters are presented on the bus.

The SL-Series libraries will support 6 + 2 characters.   Refer to 1014539.1 for further details. 





Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.