Solution Type  Technical Instruction Sure

Solution  1015927.1 :   VTL - What do the mgtpipe messages mean?  


Related Items
  • Sun StorageTek VTL Storage Appliance
  •  
  • Sun StorageTek VTL Prime System
  •  
  • Sun StorageTek VTL Plus Storage Appliance
  •  
  • Sun StorageTek VTL Value System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Virtual Tape>SN-TP: VTL
  •  
  • .Old GCS Categories>Sun Microsystems>Storage - Tape>Tape Virtualization
  •  

PreviouslyPublishedAs
224879


Applies to:

Sun StorageTek VTL Storage Appliance - Version: 4.0 - Build 1221 and later   [Release: 4.0 and later ]
Sun StorageTek VTL Plus Storage Appliance - Version: 1.0 - Build 1323 to 2.0 - Build 1656   [Release: 1.0 to 2.0]
Sun StorageTek VTL Value System - Version: 1.0 - Build 1323 and later    [Release: 1.0 and later]
Sun StorageTek VTL Prime System - Version: 1.0 - Build 1813 to 1.1 - Build 2076   [Release: 1.0 to 1.0]
All Platforms
.
***Checked for relevance on 05-08-2011*** (dd-mm-yyyy)

Goal

To determine what the Callhome mgtpipe messages mean in a VTL?

Example Messages:
1. Message: Rcv'd mgtpipe cmd: 'tle_vdevop 39122 131 1'
    Message: Rcv'd mgtpipe cmd: 'tapelocation 131 [V50166] 2 4 86 13'


2. Message: Rcv'd mgtpipe cmd: 'tle_expand 39136 131 87040 5120'

3. Message: Rcv'd mgtpipe cmd: 'tle_vdevop 39342 131 0'
    Message: Rcv'd mgtpipe cmd: 'tapelocation 131 [V50166] 1 4 86 -1'

Solution


What does each message mean?

Messages #1:
May 16 02:30:11 nbvtlp05 ipstorcomm [mgtpipe_exec.c:pipe_thread:879][14125]: Rcv'd mgtpipe cmd: 'tle_vdevop 39122 131 1'
May 16 02:30:11 nbvtlp05 ipstorcomm [mgtpipe_exec.c:pipe_thread:879][14125]: Rcv'd mgtpipe cmd: 'tapelocation 131 [V50166] 2 4 86 13'
Analysis:
The messages indicates that the tape with barcode number V50166 was loaded to drive 13.

Message #2:
May 16 02:30:35 nbvtlp05 ipstorcomm [mgtpipe_exec.c:pipe_thread:879][14125]: Rcv'd mgtpipe cmd: 'tle_expand 39136 131 87040 5120'

Analysis:
The message indicates that a tape was expanded.

Messages #3:
May 16 02:37:54 nbvtlp05 ipstorcomm [mgtpipe_exec.c:pipe_thread:879][14125]: Rcv'd mgtpipe cmd: 'tle_vdevop 39342 131 0'
May 16 02:37:54 nbvtlp05 ipstorcomm [tape_cmd.c:disableVTape:1637][14125]: isTLEBusy() = 0

May 16 02:37:54 nbvtlp05 ipstorcomm [mgtpipe_exec.c:pipe_thread:879][14125]: Rcv'd mgtpipe cmd: 'tapelocation 131 [V50166] 1 4 86 -1'
Analysis:
The messages indicates that the tape with barcode number V50166 was unloaded from a drive after make sure the TLE was not busy.


Conclusion:
These Callhome alert messages are informational.  No action is needed.