Solution Type Technical Instruction Sure Solution 1015312.1 : SL8500 - What are the Reserved WWNs Used After the WWN on the SL8500
PreviouslyPublishedAs 223350 Applies to:Sun StorageTek SL8500 Modular Library System - Version Not Applicable and laterAll Platforms Checked for relevance on 13-Aug-2012. GoalReserved WWNs Used After the WWN on the SL8500. FixSteps to Follow
Engineering has published a file of all known past and future WWN seeds to Sales Support. We get allocated WWNs to use in the libraries once a year, so we cannot assign WWN seeds longer into the future than our current allocation. The number in the list is the WWN seed in the library. The WWN seed can be obtained from the SL8500 with the CLI "prom print" command. Unfortunately, the permissions for this command are "engineering only". Engineering has requested that these permissions change so that the service and advsrv account can use the command as part of the crimson requirements. No time frame has been provided as to when this will be available. The library WWN cannot be obtained from SL Console as far as I can see. The best chance to determine the library WWN from the library is to obtain a drive WWN using SL Console, and calculate the library WWN using the "SL8500 WWN Usage.doc". SL8500 WWN USAGE
The Seed WWN value is assigned to each library by manufacturing based on the Serial Number of the machine. The code usage of this is explained below!
For Example , with a seed value of 500104F00078CB0E the library code reserves the first 16 (10Hex) values for the Library Fibre interfaces, a possible 8 ports with a possible 8 nodes depending on the configuration. The HBT card (drive interface) is then given the drive dWWN base value of 500104F00078CB1E in this case!
The drive's WWN's are assigned by the Drive Bay Number, starting with drive bay 1 and ending with drive bay 64.
Example: Drive Bay 1 Node Name 500104F00078CB1E Drive Bay 1 Port A Name500104F00078CB1F Drive Bay 1 Port B Name500104F00078CB20 Drive Bay 2 Node Name500104F00078CB21 Drive Bay 2 Port A Name500104F00078CB22 Drive Bay 2 Port B Name500104F00078CB23 ----------------_ETC_------------------- Drive Bay 64 Node Name500104F00078CBDB Drive Bay 64 Port A Name500104F00078CBDC Drive Bay 64 Port B Name500104F00078CBDD
DRIVE BAYS
Drive Bay 1 = 1,4,2,1,4 Drive Bay 2 = 1,4,1,1,4 Drive Bay 3 = 1,4,-1,1,4 Drive Bay 4 = 1,4,-2,1,4 Drive Bay 5 = 1,4,2,1,3 ------ETC---------